P 2500 - P 5000
21
Empty conduits
Use separate conduits for the power line and the control leads.
Use an additional (separate) conduit for each induction loop.
The distance between the conduits should be as large as possible.
Drawing 5
Requirements regarding the foundation
A minimum concrete strength class of C20/25 (or higher)
The use of heavy duty anchor bolts (M12).
Observe the foundation dimensions quoted in this manual. The installation
distance between the barrier housing and the foundation edge has to be
approx. 100mm.
WARNING!
Risk of injury by insufficient fastening!
Tilting barrier housings can result in severe injuries.
Before installation ensure a safe stand of the barrier
housing.
Do not lean the barrier boom against a wall or similar
before installation. Store the boom horizontally only.
Install the barrier housing as specified.
Use the recommended heavy duty anchor bolts M12, at
least M10 is required.
During maintenance check the housing for correct
fastening on the foundation.
Содержание P 2500
Страница 14: ...P 2500 P 5000 13 4 Declaration of incorporation Drawing 2 ...
Страница 20: ...P 2500 P 5000 19 7 2 Mounting dimensions Drawing 3 ...
Страница 47: ...P 2500 P 5000 46 8 4 Circuit diagram Drawing 34 ...
Страница 48: ...P 2500 P 5000 47 Drawing 35 ...
Страница 49: ...P 2500 P 5000 48 Drawing 36 ...
Страница 50: ...P 2500 P 5000 49 Drawing 37 ...
Страница 51: ...P 2500 P 5000 50 Drawing 38 ...
Страница 52: ...P 2500 P 5000 51 Drawing 39 ...
Страница 55: ...P 2500 P 5000 54 10 Layout exploded drawing Drawing 41 ...