P 2500 - P 5000
44
3.
Terminals
41 + 42
Push button CLOSE (BTZ2)
NC contact or
bridge
4.
Terminals
43 + 44
Push button STOP (BTS)
NC contact or
bridge
5.
Terminals
21 + 22
Safety contact profile CLOSE (SLZ)
8.2kOhm
resistor
Table 9
After installing and connecting all the equipment, the following LEDs have to
light:
1.
Vp
Is lit, when the supply voltage is switched on.
2.
BTZ2 Is lit, when contact BTZ2 is closed.
3.
BTS
Is lit, when contact BTS is closed.
4.
Bm.
Is lit, when the boom-missing contact is closed.
Table 10
Plug
Socket label Function
1
12V
Uext 12V, max. 500mA
2
Gnd
Ground
3
24V
Uext 24V, in total with terminal 5 and 7 max.
1500mA
4
Gnd
Ground
5
24V
Uext 24V, in total with terminal 3 and 7 max.
1500mA
6
Gnd
Ground
7
24V
Uext 24V, in total with terminal 3 and 5 max.
1500mA
8
Gnd
Ground
9
Multi1
Multi-functional relay 1, potential-free, max.
24VDC/1A
10
11
Multi2
Multi-functional relay 2, potential-free, max.
24VDC/1A
12
13
Multi3
Multi-functional relay 3, potential-free, max.
24VDC/1A
14
15
Multi4
Multi-functional relay 4, potential-free, max.
24VDC/1A
16
17
Multi5
Multi-functional relay 5, potential-free, max.
24VDC/1A
18
19
Multi6
Multi-functional relay 6, potential-free, max.
24VDC/1A
20
Содержание P 2500
Страница 14: ...P 2500 P 5000 13 4 Declaration of incorporation Drawing 2 ...
Страница 20: ...P 2500 P 5000 19 7 2 Mounting dimensions Drawing 3 ...
Страница 47: ...P 2500 P 5000 46 8 4 Circuit diagram Drawing 34 ...
Страница 48: ...P 2500 P 5000 47 Drawing 35 ...
Страница 49: ...P 2500 P 5000 48 Drawing 36 ...
Страница 50: ...P 2500 P 5000 49 Drawing 37 ...
Страница 51: ...P 2500 P 5000 50 Drawing 38 ...
Страница 52: ...P 2500 P 5000 51 Drawing 39 ...
Страница 55: ...P 2500 P 5000 54 10 Layout exploded drawing Drawing 41 ...