P 2500 - P 5000
26
Drawing 11
4. Now retighten the four screws (M12x30 ISO 4762) at the clamping piece
with 88.5 lbf ft.
7.5.1
Installation – Boom connector left side
The barrier models TF 1203/0001-1204/0001 and XP 1203/0001-1204/0001
are prepared at the factory to mount the boom on the right side. At the left side
a cap is mounted to cover the main shaft opening.
Converting from barrier boom right to barrier boom left:
1. Remove the barrier hood.
2. Detach the cover cap at the left housing side as described in the following
drawing. First pull the spring sheet upwards (1), then turn the cover cap
approx. 60° (2) and pull it upwards (3).
Drawing 12
3. Disconnect the boom connector from the right side, if already mounted.
Connect it to the left side.
4. Mount the cover cap and the spring sheet at the right housing side.
Содержание P 2500
Страница 14: ...P 2500 P 5000 13 4 Declaration of incorporation Drawing 2 ...
Страница 20: ...P 2500 P 5000 19 7 2 Mounting dimensions Drawing 3 ...
Страница 47: ...P 2500 P 5000 46 8 4 Circuit diagram Drawing 34 ...
Страница 48: ...P 2500 P 5000 47 Drawing 35 ...
Страница 49: ...P 2500 P 5000 48 Drawing 36 ...
Страница 50: ...P 2500 P 5000 49 Drawing 37 ...
Страница 51: ...P 2500 P 5000 50 Drawing 38 ...
Страница 52: ...P 2500 P 5000 51 Drawing 39 ...
Страница 55: ...P 2500 P 5000 54 10 Layout exploded drawing Drawing 41 ...