Electrostatic Technology, Inc
FlexiCoat
®
Model 300 Coater
20 Serial
#20158
8.2
POWDER COLLECTOR AND COATER CONTROLS
(continued)
HIGH VOLTAGE
ON/OFF Selector Switch
Enables the High Voltage to be turned
"ON" when using the Electrostatic Fluid
Bed.
Should be in the "OFF" position when
using the Optional Conventional Fluid
Bed. Feature.
HIGH VOLTAGE ADJUST
Adjustable Potentiometer
Adjusts the output of the High Voltage
Multiplier (0-80 kV).
HIGH KVA METER
Digital Meter
Indicates the voltage being supplied by the
High Voltage Multiplier when the
Footswitch is pressed.
HIGH VOLTAGE
ON INDICATOR
Indicator Light
Indicates that High Voltage is "ON" and
being supplied to the Coating Bed.
COATER VIBRATOR
ON/OFF Selector Switch
Turns the Coater Bed Vibrator "ON" or
"OFF" to assist in fluidization if required.
Intensity of vibration is adjusted on
Vibrator itself.
EMERGENCY STOP
Pushbutton
Shuts off the Powder Collector blower.
Shuts off power to system electrical and
pneumatic devices.