Electrostatic Technology, Inc
FlexiCoat
®
Model 300 Coater
16 Serial
#20158
7.4
CONTROLS
7.4.1 Footswitch
1.
Locate the Coater Footswitch and position in front of the Coater Station.
The Footswitch is already pre-wired to the electrical controls.
7.4.2 Settings
1.
Press COLLECTOR START pushbutton on the Control Panel. This will
turn the Blower Motor "ON".
2.
Turn COATER BED ON/OFF Switch to "ON" position.
3.
Adjust the Filter Pulser Air Pressure to 30 psi (2 bar).
4.
Adjust the Coating Bed Air Pressure to 45 psi (3 bar).
5.
If using Coating Bed in the "Hot Dip Mode", turn HIGH VOLTAGE
ON/OFF Switch to "OFF" position.
6.
If using Coating Bed in the "High Voltage Mode", turn HIGH
VOLTAGE ON/OFF Switch to "ON" position.
7.
Press Footswitch to apply fluidizing air in the "Hot Dip Mode" or
fluidizing air and High Voltage in the "High Voltage Mode".
CAUTION:
Never turn the High Voltage ON/OFF Switch to "ON"
when in the "Hot Dip Mode".
7.5
FLUIDIZING HOPPER/POWDER FEED PUMP
1.
Locate the Fluidizing Hopper/Powder Feed Pump behind the FlexiCoat
®
Model 300 Coating System.
2.
Connect the ETI supplied 2 inch diameter vent hose from the lid of
Fluidizing Hopper to the Powder Collector.
3.
Connect the 2 ETI supplied Poly-Flo tubing lines to (1) the Air Pump located
on the lid of the Fluidizing Hopper and (2) the Fluidizer located on the lower
part of the Fluidizing Hopper.
4.
Connect the ETI supplied blue hose from the Powder Pump located on the lid
of the Fluidizing Hopper to the Feeder Tube located on top of the Coating
Bed.