7
Step 2: Set detector's parameters
1.
Go to the main menu select
[9]>[1]>[1]
(Programming
>
Devices
>
Zones)
2.
Using the arrow keys select a specific zone and press
'
√ʹ
.
3.
Set the main parameters for each zone, according to
Table 3
.
Quick
Key
Option Name
Description and Notes
9>1>1>2
Zone Type
Type of alarm this zone generates
9>1>1>3
Arm Set
Arming methods in which the zone is included.
1 (F): The zone is included in Full arming
2 (P): The zone is included in Part arming
3 (PE): The zone is included in Perimeter arming
9>1>1>4
Descriptor
Descriptors help identify the device when you operate and
program the system.
9>1>1>5
Bell (Siren)
Activate the siren when the zone is triggered
9>1>1>6
Chime
Activate the internal siren when the zone is triggered.
Note
: To
enable the chime option enable Global Chime option, [Quick key
7>12
]
9>1>1>7
Force Arm
Enables you to arm the system even if this zone is not ready. For
the force arm feature to function, you must also enable force
arming in system options.
Table 3: Parameter set
If required scroll thorough the other menu parameters and modify settings