6
3.3.1.
Detectors
Prime
supports 33 security zones. Only one detector can be registered to each zone. Zones 1-32 are
intended for wireless detectors by default. Zone 33 is an on-board hardwire zone (NC).
Step 1: Register a detector
1.
Go to the main menu select
[9]>[1]>[1]
(Programming
>
Devices
>
Zones)
2.
Using the arrow keys, select a specific zone and press
'
√ʹ
. The system initiates
Registration mode.
3.
Send two transmissions from the detector. A confirmation sound is heard after each
successful signal (chime sound). After two successful transmissions a confirmation beep
is heard.
Sending the transmissions can be done in several ways, as summarized in
Table 2
.
Device
Device P/N
Sending Transmissions
PIR Detectors
EL-2745/2745PI
EL-2600/EL-
2600PI/EL-2645/
EL-2645PI
Apply battery power. Place the mode jumper over
pins 2 and 3 (Radio Mode); the LED flashes.
OR
Depress the tamper switch twice, in rapid
succession.
Magnetic contact
EL-2601
When you apply battery power, and the tamper
switch is open, the device enters test mode during
which a transmission is sent every few seconds. You
can terminate the test mode by closing the tamper
switch.
Flood Sensor
EL-2661
Universal
Transmitter
EL-2602
Glass break
EL-2606
Smoke Detector
EL-2603
Press the test button. Make certain that the
transmission LED is lit momentarily
.
Wait for five
seconds, then press the test button again.
Table 2: Transmission summary
4.
After the detector is successfully registered the display shows:
'Save
?'
Press
'
√ʹ
to confirm and continue entering other parameters for the chosen device (see
section below) or press
X
to go back and enroll additional zones.