TSE-P 04.00 EB
46/50
599 34 22-16
EXAMPLES OF CONFIGURATION
Configuration code:
A2A7808080E691F2
POSITION:
0
1
2
3
4
5
6
7
8
9
10
(A)
11
(B)
12
(C)
13
(D)
14
(E)
15
(F)
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
↓
VALUE:
A
2
A
7
8
0
8
0
8
0
E
6
9
1
F
2
TABLE OF CYCLE PHASE LEDS
On models not featuring the display window, it is advisable, before beginning the configuration procedure, to
convert the digits of the configuration code into binary format. To do this, prepare a table of the values to be
entered, which will be displayed by the second group (B) of washing phase LEDs (the positions, indicated by
the second group of 4 LEDs, are not modified).
0
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
A
b
C
d
E
F
❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ●
●
●
●
●
●
●
●
❍ ❍ ❍ ❍ ●
●
●
● ❍ ❍ ❍ ❍ ●
●
●
●
❍ ❍ ●
● ❍ ❍ ●
● ❍ ❍ ●
● ❍ ❍ ●
●
PO
SIT
IO
N
❍ ● ❍ ● ❍ ● ❍ ● ❍ ● ❍ ● ❍ ● ❍ ●
● ❍ ● ❍ ● ❍ ● ❍ ● ❍ ● ❍ ● ❍ ● ❍
❍ ❍ ❍ ● ❍ ❍ ❍ ❍ ❍ ❍ ●
● ❍ ❍ ● ❍
●
●
●
● ❍ ❍ ❍ ❍ ❍ ❍ ●
● ❍ ❍ ●
●
❍ ❍ ❍ ● ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ●
●
● ❍
VAL
U
E
A
2
A
7
8
0
8
0
8
0
E
6
9
1
F
2
CONFIGURATION
1. Access the diagnostics system.
2. Press the FABRICS or TEMPERATURE buttons until LED
L10
lights. The code relative to the first of the
16 characters of the configuration code is displayed (position zero).
3. Press the START/PAUSE button sequentially to enter the letter
A
in position
0
. If the appliance features a
display window, this will show
0-A
; if not, the wash cycle LEDs should light as shown in column 0 of the
table (i.e. the fifth and seventh LEDs).
4. Press the SKIP/RESET button to pass to the second position, and enter
2
by pressing START/PAUSE as
necessary. The display should now show
1-2
, and the LEDs should light as shown in column 1 of the
table (fourth and seventh).
5. Repeat this procedure to enter the remaining configuration digits. When all the digits have been entered,
press the SKIP/RESET button to check that the configuration code is correct.
6. Memorize the configuration code by pressing the START/PAUSE and SKIP/RESET buttons at the same
time for at least 4 seconds, so that the configuration code is memorized by the main PCB.
7. Perform the diagnostics cycle to check that the appliance operates correctly. In case of a configuration
error, error
E93
is displayed and the operation of the appliance is interrupted.