TSE-P 04.00 EB
12/50
599 34 22-16
WASHING PROGRAMMES (SEQUENCE CHARTS)
KEY TO PROGRAMMES
Description
Calibration
Drain sub-phase for calibration of the electronic pressure switch
Levels
WC
Level of water in the tub
RPC
Control level for circulation pump
DPC
Control level for drain pump
MC
Control level for motor
Pumps
OFF
Pump off
ON
Pump on
LEV
Pump on from one level of pressure switch
Water inlet valves
ELV2
Prewash
ELV3
Wash
ELV2 ELV3
P wash = softener
Refilling
NR
Normal refilling
VT
"Total exchange" refilling (virtual tank)
WL
Electronic pressure switch
AB
Safety pressure switch
Dis
Level control disabled
En
Level control enabled
Movement (motor)
OFF
Motor stopped
ON
Motor in operation
LEV
Level movement
Time
Tout
Maximum time (timeout)
Motor movement
Code
Pause (sec)
Movement (sec)
Speed (rpm)
D_MOV
12
4
55
E_MOV
3
10
55
E1_MOV
4
12
75
SE_MOV
4
24
55/40
N_MOV
8
8
55
PWL1_MOV
40
1
35
PWL3_MOV
12
1
35
SPARE_MOV
3
10
40
PWL4_MOV
57
1
35
COLD_MOV
4
12
40
CR3_MOV
Single-direction movement
80
DLD_MOV
Single-direction movement
40