TSE-P 04.00 EB
39/50
599 34 22-16
ALARM CODES
0
:
LED off 1
:
LED flashing
Alarm
code
LED
L26÷29
LED
L30÷33
Description of fault
User
code
Effect
Possible causes
E11
0
0
0
1
0
0
0
1
Problems with water fill in wash phase
(maximum 10 minutes for each fill phase)
E10
Cycle PAUSED
Tap closed or mains pressure insufficient; solenoid
valve; hydraulic circuit of pressure switches; pressure
switches; wiring; main PCB
E21
0
0
1
0
0
0
0
1
Problems with water drain in wash phase
(maximum 10 minutes for each drain phase)
E20
Cycle PAUSED
Drain hose obstructed; filter blocked; drain pump;
pressure switches; wiring; main PCB
E31
0
0
1
1
0
0
0
1
Electronic pressure switch circuit faulty
(frequency of pressure switch signal out of limits)
---
Cycle blocked
with door closed
Electronic pressure switch; wiring; main PCB
E32
0
0
1
1
0
0
1
0
Incorrect calibration of electronic pressure switch
(electronic pressure switch level different from 0-66
mm after initial calibration drain and anti-boiling
pressure switch on "empty")
---
Cycle PAUSED
Tap closed or mains pressure insufficient; solenoid
valve; hydraulic circuit of pressure switches; pressure
switches; wiring; main PCB
E33
0
0
1
1
0
0
1
1
Incongruency between level of electronic pressure
switch and level of anti-boiling pressure switch 1
(duration of fault at least 60 seconds)
---
Cycle blocked
with door closed
Hydraulic circuit of pressure switches; electronic
pressure switch; pressure switch; wiring; main PCB
E34
0
0
1
1
0
1
0
0
Incongruency between level of electronic pressure
switch and level of anti-boiling pressure switch 2
(duration of fault at least 60 seconds)
---
Cycle blocked
with door closed
Hydraulic circuit of pressure switches; electronic
pressure switch; pressure switch; wiring; main PCB
E35
0
0
1
1
0
1
0
1
Water level too high
(level of electronic pressure switch higher than
300mm for more than 15 seconds)
---
Cycle blocked
with door closed
and water drain to
120mm
Solenoid valve; hydraulic circuit of pressure switches;
pressure switches; wiring; main PCB
E36
0
0
1
1
0
1
1
0
"Sensing" circuit of anti-boiling pressure switch 1
faulty
(input signal to microprocessor always 0V or 5V)
---
Cycle blocked
with door closed
Main PCB
E37
0
0
1
1
0
1
1
1
"Sensing" circuit of anti-boiling pressure switch 2
faulty
(input signal to microprocessor always 0 - 5V)
---
Cycle blocked
with door closed
Main PCB