TSE-P 04.00 EB
33/50
599 34 22-16
DIAGNOSTICS / CONFIGURATION SYSTEM
ACCESS TO THE DIAGNOSTICS / CONFIGURATION SYSTEM
Using a single procedure, it is possible to access both the diagnostics and configuration systems. After
accessing this function, the following operations can be performed:
-
control of the operation of each of the components in the appliance.
-
analysis of alarm conditions
-
configuration of the main PCB
To access the system:
press the SKIP/RESET button to cancel the programme previously selected and switch off the appliance.
press the START/PAUSE button together with the SKIP/RESET button and then, holding down both
buttons, press the ON/OFF button to switch on the appliance.
hold both buttons (START/PAUSE and SKIP/RESET) down until the buzzer sounds and the LEDs begin
to flash (about 4 seconds)
At this point, the display board is checked and the LEDs (and, if featured, the display window) light in
sequence.
If the main PCB has not been configured, it is possible only to perform the test on the display board and the
configuration procedure
.