2007-10 SOI/DT-mdm FCPD-dp Quality-fz
27/59
599 70 32-47
NO
YES
Empty the machine.
Are pressure switch hose and air trap
system free? (You can disconnect the
hose and blow in it to check if the system
is free)
-see fig. 2 and 8-
YES
YES
NO
NO
NO
E35: Water level too high
E35
The electronic board measures a water level from analogic pressure switch
higher then 300 mm for more then 15 seconds.
E35
Tests to be performed:
YES
If there are traces of burning on the
circuit board, refer to page
59
Clean/change the hoses and/or air trap
system and repeat completely the
diagnostic cycle to check for further
alarm conditions.
Replace the inlet
valves and
repeat
completely the
diagnostic cycle
to check for
further alarm
conditions.
Get inside
diagnostic cycle
at
step 8
. After
door lock is the
machine also
filling water?
Replace the
analogic
pressure switch
and run the
diagnostic cycle
to check for
further alarm
conditions.
Is the cable
between main
board and
analogic pressure
switch connected
correctly on both
sides?
Replace the main
board and repeat
completely the
diagnostic cycle
to check for
further alarm
conditions.
Is the machine
filling water when
main switch is
turned OFF?
Reconnect
and/or replace
the cable and do
the diagnostic
cycle completely
again to check
for further alarm
conditions.
fig. 8
Fig.2