2007-10 SOI/DT-mdm FCPD-dp Quality-fz
50/59
599 70 32-47
Tests to be performed:
E83: Error in reading the programme selector code
E83
Code for the position of the selector not included in configuration data or configuration error
E83
Switch the appliance on and
turn the programme selector
to every position. Wait 10
seconds at each position
before passing to the next
one. Does alarm E83
reappear?
Replace the circuit board
and restart the diagnostic
cycle to check for further
alarm conditions.
NO
Restart the diagnostic
cycle to check for further
alarm conditions.
YES