2007-10 SOI/DT-mdm FCPD-dp Quality-fz
42/59
599 70 32-47
NO
YES
NO
YES
E61: Insufficient heating during washing
E61
Maximum heating time exceeded
Â
SOMETIMES THE ALARM CAN BE CAUSED BY THE POWER VOLTAGE TOO LOW!
E61
Tests to be performed:
Measure the value of the
NTC sensor across contacts
J9-9 and J9-8 of the circuit
board connector.
Is the value correct?
(between 5.7 and 6.3 K
Ω
at
20°C)
Detach the connector and
measure the value directly
on the NTC sensor.
Is the value correct?
- see fig. 14 -
(between 5.7and 6.3 K
Ω
at
20°C)
Replace the NTC
temperature sensor and
restart the diagnostic
cycle to check for further
alarm conditions.
Replace the circuit board
and restart the diagnostic
cycle to check for further
alarm conditions.
Check/replace the wiring
and restart the diagnostic
cycle to check for further
alarm conditions.
If there are traces of burning on
the circuit board, refer to page
59
J9
J10
J7
J2 J1
U3
Fig.4
fig. 14
Circuit
board