5.2 Reading the alarm codes
It is possible to display the last three memorised alarms in the FLASH memory
of the electronic board:
•
Enter diagnostic mode (par. 4.1).
•
Irrespective of the type of PCB and configuration, turn the programme
selector
clockwise
to the
tenth position
.
•
The last alarm is displayed.
•
To display the previous alarms, press sequentially the left button of the
START/PAUSE button (as represented in figure).
•
To return to the last alarm, press the START/PAUSE button.
5.2.1 Alarm
displaying
AEG Version:
The alarm is displayed by a repeated flashing sequence of the START / PAUSE
button with yellow and red light (0,5 seconds on, 0,5 seconds off with a 2,5
second pause between the sequences).
•
button indicator START / PAUSE with yellow light
→
indicates the first digit of
the alarm code (family)
•
button indicator START / PAUSE with red light
→
indicates the second digit
of the alarm code (internal number of the family)
These two LEDs are featured in all models.
Other versions:
The alarm is displayed by a repeated flashing sequence of the START / PAUSE
button with red and green light (0,5 seconds on, 0,5 seconds off with a 2,5
second pause between the sequences).
•
LED indicator START / PAUSE with red light
→
indicates the first digit of the
alarm code (family)
•
LED indicator START / PAUSE with green light
→
indicates the second digit
of the alarm code (internal number of the family)
These two LEDs are featured in all models
.