4 DIAGNOSTIC
SYSTEM
4.1 ACCESS TO THE DIAGNOSTIC CYCLE
1. Switch off the appliance.
2. Press and hold down the
START/PAUSE
button and the nearest
OPTION button
simultaneously (as represented in figure).
3. Holding down both buttons, switch the appliance on by turning the programme selector
one
position clockwise
.
4. Continue to hold down the buttons until the LEDs begin to flash (at least 2 seconds).
In the first position, the cycle tests the operation of the buttons and the relative LEDs. If the
selector is turned
clockwise
, the cycle performs the diagnostics for the various components and
reads the alarm codes.
4.2
Exiting the diagnostic system
→
To exit the diagnostic system, switch off, switch on and switch off again the appliance.