Hold the mounting plate in place with a bent
coat hanger. Open the valve lid and slide the
valve flange first over the end of the coat hang-

er. Keep ten-
sion on the coat
hanger while
inserting the
valve into the
mounting plate
with a twisting
motion (See
Fig. 11). Do not
use glue; the
built in mount-
ing plate gasket
will provide a
positive seal.
Align the screw

holes in the valve with those in the mounting
plate. Using the screws provided, secure the
valve in place. Use the extra short screw if the
longer is going to interfere with the tubing
behind. Do not over tighten.

Apply glue to an adequate length of tubing and
aim it upwards through the hole and into the 90
degree dual elbow fitting on the back of the
mounting plate. Join this branch line to the trunk
line using a 90 degree sweep tee.

If the inlet valve is to be serviced from the attic,

shorter pieces of tubing joined by couplings
may be required due to overhead space restric-
tions. Precut these pieces and work quickly to
prevent the on the end of the tubing from drying
before it reaches the fitting at the valve below.

d) Floor Valves

To install a floor inlet, drill a pilot hole with a coat
hanger and check the location as previously
described. When you are sure that the pro-
posed location will not be blocked by a joist or
other obstruction, cut a hole in the carpet slight-
ly larger than your 2-1/4" (5.7cm) drill bit. Drill a
2-1/4" (5.7cm) hole in the floor. Chisel or saw
this hole larger to accommodate the inlet valve
low-volt connections (Fig. 12). 

Assemble an adapter reducer bushing and
some low-volt wire to an inlet valve. Screw the
valve to the floor. Repeat until all inlets are
installed (Fig. 13).

e) Closet Wall Installation—Existing
Structure

Often it is only practical to install your system
with the line coming up through the floor inside
a closet and
then through
both sides of
the wall. To use
this method,
select suitable
inlet valve
location, exer-
cising same
precautions as
for normal wall
i n s t a l l a t i o n .
Using a length
of coat hanger,
pierce a hole
through both
walls (Fig. 14).

Содержание Afuera

Страница 1: ...Do It Yourself Planning Installation Manual for your new AFUERATM Central Cleaning System ...

Страница 2: ...d than wall valves and sometimes are the only practical installation They have some dis advantages as the hose must be inserted at the floor level rather than at a more convenient wall height Wall height is a matter of individual preference Some homeowners prefer the inlet at a convenient fingertip height about 30 inches 76cm while oth ers want it to match the electric outlet height STEP 2 Choose ...

Страница 3: ...imum stud width for sufficient clearance for inner wall mounting bracket assembly is 2 3 4 7cm See Fig 3 above b Using METAL Stud Mounting Bracket Centered at the desired height above floor level cut an almost square opening 2 3 4 7cm wide by 2 1 2 6 35cm high in the wall directly above the 2 1 4 5 7cm sole plate hole Cut or file two 3 4 1 9cm high triangular pieces above and below the almost squa...

Страница 4: ... of tubing joined by couplings may be required due to overhead space restric tions Precut these pieces and work quickly to prevent the cement on the end of the tubing from drying before it reaches the fitting at the valve below c Using PLASTIC Stud Mounting Bracket Having determined the location is suitable cut a 2 1 2 6 35cm x 4 3 8 11cm hole in the wall at the desired inlet valve loca tion See F...

Страница 5: ...ce restric tions Precut these pieces and work quickly to prevent the on the end of the tubing from drying before it reaches the fitting at the valve below d Floor Valves To install a floor inlet drill a pilot hole with a coat hanger and check the location as previously described When you are sure that the pro posed location will not be blocked by a joist or other obstruction cut a hole in the carp...

Страница 6: ...e metal bracket Attach wires to low voltage terminals at rear of inlet valve Place inner wall assembly lengthwise through wall opening and arrange assembly so that metal bracket is flush with inside surface of wall Screw inlet to wall as described previous ly in STEP 1 then complete as per Fig 16 f Wall Valve Installation New Construction Select a probable location for inlet valve and drill a pilo...

Страница 7: ...ing or low voltage wire to pass PVC tubing through to hold it in position while you work Push a length of PVC tubing up into bottom of inlet valve assembly Bear in mind tube enters all fittings approximately 3 4 1 9cm Measure cut and slip fit this vertical line to main horizon tal line with a 90 degree sweep elbow To avoid potential clogging problems when installing tubing and fittings here are so...

Страница 8: ... provided Do not cement this connection to the power unit in case you wish to remove at some future date Do not install power unit where the ambient temperature exceeds 120 degrees Fahrenheit 48 9 degrees C NOTE For top loading units follow directions provided with unit This unit may be exhausted to exterior to expel fumes germs and some noise Use the same tubing and fittings as before If vented t...

Страница 9: ...circuit and has a ground plug that looks like the plug illustrated in figure 21 for North American units For 220 230 240 volt units consult your local building code electri cian Make sure that the appliance is connected to an outlet having the same configuration as the plug No adapter should be used with this appliance Check power unit On Off switch and all inlet valves for operation This power un...

Страница 10: ...air face fingers and loose clothing away from any openings 9 Do not pick up cigarettes live hot ashes matches or similar materials 10 Never operate vacuum without dust bag and or filter in place 11 To disconnect turn all controls to the OFF position then remove plug from outlet 12 Never handle plug cord or power unit with wet hands 13 Electric shock could occur if used on wet surfaces 14 Use extra...

Отзывы: