background image

Rev. 21.11.2018

 

Id.No. DOK30616

 

 

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 

 

 
 
 
 

 

BUS BODY ELECTRONICS

 

 

 

 

SC600 INDIEN 

 

 

Operating instructions 
- Busdriver 

 

 

Содержание SC600 Indien

Страница 1: ...Rev 21 11 2018 Id No DOK30616 BUS BODY ELECTRONICS SC600 INDIEN Operating instructions Busdriver ...

Страница 2: ...y 4 1 5 Mode overview 5 2 Use 6 2 1 Activation deactivation 6 2 1 1 Activation 6 2 1 2 Deactivation 6 2 2 Auto mode 6 2 2 1 Activation 6 2 2 2 Deactivation 6 2 3 Configuring the blowers manually 7 2 3 1 Activating the controller manually 7 2 3 2 Setting blower level 7 2 4 Fresh air recirculating air function 8 2 5 Setting the temperature 8 2 6 Errors 9 2 6 1 Error detection mode 9 2 6 2 Error over...

Страница 3: ...ode activated Cooling mode 6 Figure 7 SC600 Auto mode deactivated 6 Figure 8 SC600 setting the blower level manually 7 Figure 9 SC600 recirculating air function activated 8 Figure 10 SC600 setting the temperature 8 Figure 11 SC600 errors 9 Figure 12 SC600 access code entry 9 Figure 13 SC600 reading out the error code 9 Figure 14 SC600 normal operating display 9 List of Tables Table 1 SC600 India e...

Страница 4: ...ntrol element integrated into the dashboard control device as an interface between human and machine and a rooftop air conditioning system or floor heater The roof air conditioning system can take over ventilation cooling and heating functions depending on the version In addition the controller for the air conditioning components can operate automat ically To do so the bus driver simply has to set...

Страница 5: ...of the display 1 Display 2 On off button 3 UP 4 DOWN 5 Function status light 6 Blower button 7 Fresh air recirculating air button 8 Auto button A Desired value display room temperature B Blower level manual C Cooling mode D Heating mode E Recirculating air on F Error display G Auto mode active H External temp display 1 2 3 4 6 7 8 5 Figure 1 SC600 control panel B H C A D F G E ...

Страница 6: ...functions and infor mation summarized under point 2 as well as Error mode The normal operat ing display includes all of the elements provided here in the example Error detection mode Mode to display all errors that occurred and their probability of occurrence For more infor mation see points 2 6 1 and 2 6 2 The error display in cludes all of the ele ments provided here in the example ...

Страница 7: ...status light and func tion symbol light up on the display Figure 5 2 2 2 Deactivation Press button if Auto mode is on Mode is off corresponding status light and function symbol are off Figure 7 Note Can only be activated when the ignition is switched on Note If Auto mode is on the system automatically turns on Cool ing Mode as needed Figure 6 Figure 4 SC600 start display Figure 5 SC600 Auto mode a...

Страница 8: ... set in level increments of 0 blower speed 0 to 10 blower speed 100 Press button Blower level 1 Press button Blower level 1 Note When Auto mode is deactivated the air conditioning com pressor after a run time of 90 seconds max and the heater are turned off The blowers will continue to be controlled automatically if the blower level was not manually configured Note Configurations can only be applie...

Страница 9: ...ctivates the function that best supports reaching the desired temperature stipulated Pressing the button again within 10 minutes toggles and resets the function for 10 minutes 2 5 Setting the temperature Press button Desired temperature 1 C Press button Desired temperature 1 C Note If the fresh are vales are closed the corresponding status light and the display symbol will light up Figure 9 Note T...

Страница 10: ...ce count 1 here will be displayed Figure 13 if the correct code is en tered Scroll through the error codes with or Reset the counter with after resetting the coun ter shower the value 1 if the error persists 2 6 1 4 Ending Press button for 2 seconds Normal operating display appears Figure 14 Note If errors are present the function symbol blinks on the display Figure 11 The warning symbol will not ...

Страница 11: ...ective sensor Wiring harness defective F021 Floor temperature sensor Defective sensor Wiring harness defective F022 Condenser pressure sen sor Defective sensor Wiring harness defective F025 High pressure Low pressure Brief system overload because of high motor speed at high environ mental temperature The system turns off for 5 minutes and tries to restart If the error code persists consult our ser...

Страница 12: ...Valeo Thermal Commercial Vehicles Germany GmbH Postfach 1371 82198 Gilching Germany Tel 49 0 8105 7721 0 Fax 49 0 8105 7721 889 www valeo thermalbus com service valeobus valeo com ...