SERVICE MANUAL Blast Chiller Freezer 100 - 200
See reference instructions provided with the INSTALLATION MANUAL for each model present on web
CODE: 595R361... /595R489..
2.8.1 Power connection on bcf
The units are not predisposed the power cable, the MCA and MOP are to help to determine the cable and the
max protection safety device
The reference to the adsorbed current and the voltage are on the unit data plate.
The color of the main conductors present in the power cable are standard as:
Blue = N neutral
Dark= L1 Phase
Grey= L2 Phase
Brown= L3 Phase
Yellow and Green= Heart
The readings should be:
L1 / L2 / L3
+
N*
(Phase and Neutral)
~ 230 Volts
(± 6% based on European
standards
L1 and/or L2
L3
(Phase and Phase)
~ 400 Volts
L1 / L2 / L3
(Phase and Earth)
~ 230 Volts
N
(Neutral and Earth)
~ 0 Volts
(or approx. zero V)
Warning:
The combination and results obtained will permit you to find all wires: PHASE, NEUTRAL and
EARTH.
2.8.2 Power connection on bcf 208V (USA)
The units built-in
are not predisposed with power cable
.
The reference to the adsorbed current and the voltage are on the unit data plate.
The color of the main conductors present in the power cable are standard as:
White = L1 Phase
Grey = L2 Phase
Brown = L3 Phase
Yellow and Green= Heart
The readings should be:
L1 and/or L2
+
L3
(Phase and Phase)
~ 208 Volts
L1 / L2 / L3
(Phase and Earth)
~ 120 Volts
Warning:
The combination and results obtained will permit you to find all wires: PHASE, and EARTH.
NOT USE THE
PLUG!
IT IS MANDATORY
USE A PERMA-
NENTLY CONNEC-
Содержание SKCH 100
Страница 1: ...SERVICE MANUAL FREEZER 100 150 200 2019 Doc N 595R49500 Edition 0 1 00 09 2019 ...
Страница 138: ...DOC NUMBER 595R495 138 SERVICE MANUAL Blast Chiller Freezer 100 200 6 4 33 LED lamps Steps for replacing the LED lamps ...
Страница 140: ...DOC NUMBER 595R495 140 SERVICE MANUAL Blast Chiller Freezer 100 200 ...
Страница 141: ...DOC NUMBER 595R495 141 SERVICE MANUAL Blast Chiller Freezer 100 200 ATTENTION ...
Страница 148: ......