6.4.21 Outevaporator probe (green)
Steps for replacing the outevaporator probe:
147.
Follow the procedure in the [
Upper Panel
] and [
Electrical Box
] paragraphs to reach the suction
probe connector and disconnect it.
148.
Cut the insulation near the thermostatich valve to reach the suction probe (Fig. 1 phase 1).
149.
Unscrew the clamp of expansion valve bulb to release the suction probe bulb (Fig. 1 phase 2),
then pull out the suction probe bulbe (Fig. 1 phase 3).
150.
Insert the bulb of the new suction probe into the seat, then tighten the screw of the clamp. Do not
overtight the screw in order to prevent any damage to the bulbs.
151.
Restore the insulation accurately. Use a cable tie to fix the insulation and the suction probe (Fig.
2).
152.
Use cable ties to restore the wiring layout.
153.
Reassemble all the removed components following
the inverse procedure.