DOC
NUMBER
595R495
72
SERVICE MANUAL Blast Chiller Freezer 100 - 200
2.9.2 Manual Test Wizard
This is a procedure that the service can use in case automatic wizard is not enabled and where service technician
can aproach the unit using some cycle and environment to test all meccanical parts and refrigerant circuit to
ensure that the unit function well.
2.9.2.1 Start manual wizard
1. Connect the unit to power supply, make reference to paragraph
2.1.5
( electrical connection BCF)
2. Switch on the unit with the bottom make reference to paragraph
2.3.2
( description main display)
3. Enter in the setting mode and set:
1) language
2) data
3) time
4) misurament unit
5) sound
6) Touchscreen Calibration
4. Access to service area refer to paragraph
2.3.3
5. Activate the “data monitor” The “data monitor” is visible after access to service area and present in the
drawer main menu
6.
7.
8. Set the manual environment
9. Start the LITE HOT CYCLE setting:
Cavity temperature 30°C (86F)
Time to 25 minutes
10. Check in the data monitor the value of temperature as