SERVICE MANUAL Blast Chiller Freezer 100 - 200
Parameter
ID
Parameter
Description
Table
Min
Max Default
131
dPS
Delta beetwen cavity and food probe temperature during food
probe recognition
0
60
10
133
Eft
Configures appliance evaporator fans motor type. If motor with-
out speed regulation is selected, eletrical wiring and user inter-
face will be adapted accordingly
{0, “No speed regu-
lation”}
{1, “Internal in-
verter"}
{2,"External inverter}
0
2
1
135
Efn
Number of evaporator fans according to appliance model.
Set 0 to disable fans diagnostic
0
3
2
145
CPA
Cruise optimization percentage according to estimated time. Set
0 to disable optimization
0
100
0
146
dFRS
Door frame activation set temperature
-50
100
10
147
CdP
Minimum delay between consecutive compressor activations
0
240
120
148
CoFt
Maximum n° of hours with compressor OFF. After this time the
compressor will start with impluse start-up.
Set 0 to disable the impulse start-up
0
240
48
149
CnCy
Number of impluses at compressor startup
1
240
12
150
CtOn
ON time during impluse start-up
0
240
0,8
151
CtOF
OFF time during impluse start-up
0
240
8,0
164
CPE
enables/disables the compressor alarm diagnostic
{0, “Disabled”}
{1, “Enabled"}
0
1
1
165
PAt
Max number compressor protection activations before to stop
the cycle
1
240
10
166
PAL
Max compressor protection duration before to stop the cycle
0
600
10
167
CPt
Defines the compressor diagnostic type
{0, “Safety switch”}
{1, “Thermic"}
0
1
1
168
dLEM
OFF delay of compressor after OFF flow valve during Posi-
tive/Negative conserve
0
240
4
169
dLEC
OFF delay of compressor after OFF flow valve during
chilling/freezing cycles
0
240
4
170
dLCM
ON delay of flow valve during Positive/Negative conserve
0
240
4
171
dLCC
ON delay of flow valve during chilling/freezing cycles
0
240
4
172
bYVE
enables/disables the additional bypass flow valve
{0, “Disabled”}
{1, “Enabled"}
0
1
0
173
bYVT
The additional bypass valve is activated if Out evaporator Tem-
perature is greater or equal than this parameter.
-50
125
-10
174
oEEC
Calibration applied when the cavity probe is used to drive by-
pass valve (out evaporator error)
-50
125
0
Содержание SKCH 100
Страница 1: ...SERVICE MANUAL FREEZER 100 150 200 2019 Doc N 595R49500 Edition 0 1 00 09 2019 ...
Страница 138: ...DOC NUMBER 595R495 138 SERVICE MANUAL Blast Chiller Freezer 100 200 6 4 33 LED lamps Steps for replacing the LED lamps ...
Страница 140: ...DOC NUMBER 595R495 140 SERVICE MANUAL Blast Chiller Freezer 100 200 ...
Страница 141: ...DOC NUMBER 595R495 141 SERVICE MANUAL Blast Chiller Freezer 100 200 ATTENTION ...
Страница 148: ......