Installation manual
9.4
Machine connection
Connect the earth and other wires according to the table.
Single-phase connection
Three-phase connection
1NAC
L1
N
3AC
L1
L2
L3
1AC
L1
L2
3N AC
L1
L2
L3
N
1N/1
L1
L2/N
3N AC
L1
L2
L3
N
Single phase machines may be powered either by connection between a phase and neutral or by connecting be-
tween two phases.
Example:
Machines for 220-240V single phase may be powered from 380V or 400V or 415V system by connection between a
phase and neutral or from 220V or 230V or 240V system by connection between two phases.
9.5
Connector with termination resistor
To maintain stability of internal data bus, it is mandatory to use the connector with termination resistor which is en-
closed with all machines.
Connect the connector with termination resistor to connection B at the rear of the machine.
B
fig.X01168A