Installation manual
19
mm
A
B
C
D
E
F
G
H
WH6–7
495
460
110
125
375
170
40
100
WH6–8
495
460
110
125
375
170
40
100
WH6–11
575
465
130
140
455
185
35
95
WH6–14
635
490
135
175
515
195
65
125
WH6–20
715
545
125
205
595
185
65
125
WH6–27
790
615
115
180
670
175
65
125
WH6–33
900
835
60
140
670
175
60
80
Place the machine over the two drilled holes. The holes are at the front of the machine.
Level the machine with the feet of the machine. Screw in the feet as much as possible before starting to level the ma-
chine. This will make the machine stand steadier.
The maximum height adjustment of the feet is 30 mm for WH6–7-WH6–11 and 50 mm for WH6–14-WH6–33.
Insert the expansion bolts (1) into the holes drilled in the floor. Fit the washers and nuts and tighten with tightening
torque 5 Nm.
It is of the upmost importance that the machine is placed in level, from side to side as well as front to rear.
Remount the panels when ready.