30
Installation manual
9.6.2
Inputs
Depending on machine configuration, the inputs are configured according to the following table:
Connection
Config. 22A
Config. 22B
Terminal 5
Enable start
Enable start
Terminal 6
Remote start /stop
Remote start /stop
Terminal 7
Coin 1
Coin 1
Terminal 8
Pause
Pause
The signal level for the inputs can be either 5-24V DC/AC or 100- 240V AC.
For 5-24V, connect the signal reference to terminal 3 and for 100-240V to terminal 4. The potentials on the inputs
cannot be mixed!
The figure shows an example of connecting a 24V pause signal. The program will pause for as long as the pause sig-
nal remains active (high), e.g. while waiting for central dosing system to be ready.
fig.6266