42
Installation manual
Connect the cut wires to connection 11 and 12 on the I/O board.
fig.X01689
Connect jumpers between connection 1 and 9 and between connection 2 and 10 on the I/O board.
2x
2x
fig.X01690
Steam pressure required:
• minimum: 50 kPa (0.5 kp/cm
2
)
• maximum: 800 kPa (8 kp/cm
2
)
• recommended: 600 kPa (6 kp/cm
2
)
Note!
A steam heated machine is only intended to use clean steam.