background image

ELECTRO FREEZE Soft Serve Model SL500

26

   184599-01 - 10/13

Alphabetized Parts List for Model SL500

*

As Required

**

Items Included In O-Ring Kit No. HC115536

***

LH or RH — Left or right hand is determined as you face the front of the freezer.

WC = Water Cooled       AC = Air Cooled      NLA = No Longer Available      NLU = No Longer Used

Important:  All parts shown are for standard models designed for 230V/1PH/
60HZ or 203–230V/3PH/60HZ.

PART

PART

SERIAL NUMBER

DESCRIPTION

NUMBER

QTY

   (FROM – TO)

Use only original or authorized replacement parts with this freezer.

Use of unapproved parts will void warranty.

Sanitizer-Stera Sheen (Per 4 lb. jar) ...................... HC158014A ........ * ...... D2P-908

-

Sanitizer-Stera Sheen (Per case/4 jars) ................ HC158014 .......... * ...... D2P-908

-

Sanitizer-Stera Sheen (Sample) ............................ HC158013 .......... * ...... D2P-908

-

Scale-Overrun ....................................................... HC158049 .......... * ...... D2P-908

-

Screw-HXHM 1/4-20 x 2 ZN (Switch Assy.) ........... HC160066 .......... 3 ..... D2P-908

-

A2Q

Screw-HXHM 1/4-20 x 2-1/4 ZN (Switch Assy.) ..... HC159912 .......... 3 ..... A2Q

-

Screw-SK Set 1/4-20 x 1/4 ................................... HC160495 .......... 4 ..... D2P-908

-

Screw-SK Set 5/16-18 x 3/8 ................................. HC160033 .......... 4 ..... D2P-908

-

Screw-SKHC #6-32 x 1 BKOX (Switch Assy.) ....... HC160381 .......... 6 ..... D2P-908

-

Screw-TRPM 1/4-20x1 SST (Side Panel) .............. HC159219 .......... * ...... D2P-908

-

Screw-TRPM 1/4-20x1/2 SST (Rear Panel) ........... HC160048 .......... * ...... D2P-908

-

Screw-TRPM #10-24x1/2 SST

(Front, Dispense, Trimstrip Panels) ................ HC160076 .......... * ...... D2P-908

-

Seal-Assy. Shaft Double ....................................... HC115525** ........ 2 ..... D2P-908

-

Seal-Beater Shaft ........................................... HC160557 .......... 2 ..... D2P-908

-

Washer-Double Shaft Seal ............................. HC137593 .......... 2 ..... D2P-908

-

Shaft- Assy. Beater ............................................... HC120866 .......... 2 ..... D2P-908

-

Sheave-5/8 Bore 5.50 OD (Driven) includes .......... HC153621 .......... 2 ..... D2P-908

-

Sheave-7/8 Bore 3.25 OD (Driver) includes ........... HC153626 .......... 2 ..... D2P-908

-

Shroud-Assy. Condenser (Water Cooled) .............. HC120151 .......... 1 ..... D2P-908

-

Shroud-Assy. Condenser (Air Cooled) ................... HC120788 .......... 1 ..... D2P-908

-

Sleeve-Compressor Mounting ...............................

HC151479 .......... 4 ..... D2P-908

-

Socket-Octal Terminal ........................................... HC150119 ........... 2 ..... D2P-908

-

Spacer-Panel (Side Panel) .................................... HC138456 .......... * ...... D2P-908

-

Spring-Compression MW ZN (Switch Assy.) ......... HC162323 .......... 3 ..... D2P-908

-

Strip-Terminal ........................................................ HC150795 .......... 2 ..... D2P-908

-

Stud-Assy. Cylinder 3-15/16" ................................ HC114341-05 ..... 4 ..... D2P-908

-

Содержание SOFT SERVE TWIST SL500

Страница 1: ...OPERATOR SMANUAL with Replacement Parts List H C Duke Son LLC P N 184599 October 2013 Printed in USA SOFTSERVE TWIST MODEL SL500 184599 10 13 ...

Страница 2: ......

Страница 3: ...Operator s Manual for the Electro Freeze Model SL500 Soft Serve Freezer All contents Copyright 2013 H C Duke Son LLC 2116 Eighth Avenue East Moline Illinois 61244 ...

Страница 4: ...y alert symbol but the message is the same Decals with the words DANGER WARNING or CAUTION appear on the freezer DANGER identifies the most serious hazard Decals with the words DANGER or WARNING are typically near specific hazards on the freezer General precautions are listed on CAUTION safety decals In this manual CAUTION messages with the safety alert symbol call attention to safety messages Whe...

Страница 5: ...ion and illustrations on pages iv and v of this manual to identify the decal and contact your local distributor or H C Duke Son LLC DO NOT attempt to operate the freezer until you read and understand all safety messages and the operating instructions in this manual DO NOT allow untrained personnel to maintain or service this machine Failure to follow this instruction may result in severe personal ...

Страница 6: ...ating instructions in this manual are read and understood Take notice of all warning caution instruction and information decals or labels on the freezer as shown in the figure on the following page The labels have been put there to help maintain a safeworkingenvironment The labels have been designed to with stand washing and cleaning All labels must remain legible for the life of the freezer Check...

Страница 7: ...rate unit with dispense head removed Before removing dispense head 1 Turn all control switches to OFF and 2 Disconnect all power supplies Unit may have more than one power supply Located behind the head 2 WARNING Hazardous moving parts Machine starts automatically Do not operate with panel removed HC165126 3 ...

Страница 8: ...ecifications 5 3 1 Particulars 5 3 2 Data Plate 6 3 3 ReferenceInformation 6 3 4 InstallationDate 6 3 5 Dimensions 7 4 Part Names and Functions 8 5 Operator Controls Indicators 11 5 1 Day Night Switch 11 5 2 Selector Switch 12 5 3 Reset Overload 12 5 4 Timer 12 5 5 Add Mix Indicator Light 12 5 6 Mix Feed Tube and Regulator 13 6 Disassembly and Cleaning 14 6 1 CleaningAccessories 14 6 2 Disassembly...

Страница 9: ... 9 1 NightSwitchOperation 26 9 2 DrainingProduct 27 10 Soft Serve Information 28 10 1 Overrun 28 10 2 Rerun 28 11 Routine Maintenance 29 12 Troubleshooting Table 33 PART II REPLACEMENT PARTS with ILLUSTRATIONS Refer to Part II Table of Contents for help with locating part numbers and illustrations Table of Contents continued ...

Страница 10: ...freezers Make sure all personnel responsible for equipment operation completely read and understand this manual before operating the freezer When properly operated and maintained the freezer will produce a consistent quality product If you require technical assistance please contact your local authorized Electro Freeze Distributor as follows Name Address Phone For factory service assistance contac...

Страница 11: ...If the SHOCKWATCH label indicates red and or the carton is broken torn or punctured note the damage on the carrier s freight bill and notify the carrier s local agent immediately 1 Remove the carton from the pallet and move the machine as close as possible to the permanent location 2 Remove the shipping bolts on the bottom of the freezer figure 2 1 and install either the legs or casters figure 2 2...

Страница 12: ...nual shut off valve should be installed in the water inlet line at the time of installation The water pressure must be between 35 140 psig 241 965 kPa for properoperation 4 Place the freezer in its final location and adjust the legs or casters so that it is level side to side and the front is approximately 1 4 inch lower than the rear to allow proper drainage of the freezing cylinder 2 3 Electrica...

Страница 13: ...gram pro vided for proper power connections 3 Electrical connections for model SL500 are made in the junction box located mid level behind the front panel 4 Use a flexible connection when permissible Copper wires are required for connection to freezer All materials and connections must conform to local codes and or the National Electrical Code 5 For all 3 phase freezers beater shaft rotation must ...

Страница 14: ...ight lb kg 539 244 CylinderCompressor 2HP 10000 BTU hr 1 5 kw Motor 3 2 kw Cooling HopperCompressor 1 10 hp 500 BTU hr Beater Motor 2 2 HP 1 5 kw Refrigerant Cylinder R 404a Refrigerant Hopper 134a Charge WC Cylinder lbs kg 3 75 1 70 AC Cylinder lbs kg 4 375 1 98 Charge Hopper oz kg 7 2 Cooling Air or Water Hopper qt ltr 2 16 15 1 Cylinder qt ltr 2 3 7 3 5 ...

Страница 15: ... Ampacity ___________ 3 2 Data Plate The data plate provides important information that the operator should record and have available for parts ordering warranty inquiries and service requests Figure 3 1 3 4 Installation Date Fill in the date of installation and the name address and phone number of the installer in the space provided below This information will be needed when ordering parts or ser...

Страница 16: ...ELECTRO FREEZE Soft Serve Model SL500 184599 7 Figure3 2 Electro Freeze Model SL500 The dimensions of the SL500 freezer is providedinfigure3 2below 3 5 Dimensions ...

Страница 17: ... Forms the frozen product as it is dispensed 1 HEAD DISPENSE Encloses the freezing cylinder and provides an opening for product to be dispensed 2 O RINGS HEAD Seals the head to the freezing cylinder Must be lubricated 3 PLUNGERS DISPENSE SIDE Seals the product opening in the head when closed Allows product to flow when open 4 O RINGS PLUNGER Seals the plunger in the head Must be lubricated to seal...

Страница 18: ... to the number in the figure SEAL BEATERSHAFT Sealstheopeningbetweenthe freezingcylinderandthebeatershaft Consistsofthefollowing 4 SEAL BEATERSHAFT 5 WASHER DOUBLESHAFT SEAL 1 BAR BREAKER Keepsproductblendedinthecenter ofthebeatershaft 2 SHAFT ASSY BEATER Rotatesinthefreezingcylinder blendingairandmix Ejectsproduct whendispensingplungerisopened 3 BLADE SCRAPER Scrapesthefrozenproductfromthe freezi...

Страница 19: ...into the freezing cylinder from the hopper 2 REGULATOR Provides adjustment on mix feed rate and a positive shut off of mix flow to the freezing cylinder 3 O RING TUBE Seals the opening between the hopper and mix feed tube O ring does not need lubrication The following descriptions refer to figure 4 3 The number preceding the part name corre sponds to the number in the figure ...

Страница 20: ... product agita tion The freezer will automatically cycle to maintain temperatures below 40º F 4º C Use this position when the freezer will not be in use for periods of more than an hour The following paragraphs describe the operator controls and indicators Refer to figure 5 1 for location of these controls and indicators on the freezer NOTE The dispense head must be in place before the freezer wil...

Страница 21: ...anytime switch is turned from OFF to Auto 5 Operator Controls continued 5 3 Reset Overload 3 Important If the overload trips frequently your freezer should be checked for proper product temperature overrun and voltage Contact your Electro Freeze Distributor This control protects the beater motor against failure from an overload condi tion by automatically shutting down the freezer To restart the f...

Страница 22: ...eed regulator may be adjusted within the three indent range to obtain an optimum product overrun and dispense speed 3 The largest indent setting will allow the least overrun The smallest indent setting will allow the most air in the cylinder and is used for a higher overrun see figure 5 4 During periods of idle or night operation place the mix inlet port to the closed position At this setting mix ...

Страница 23: ...necessary for cleaning sanitizing and disassembly assembly 1 HC150009 BRUSH HC158012 HANDLE 4 inch diameter with 36 inch handle used for cleaning the cylinder 2 HC158077 BRUSH 9 16 inch with 36 inch handle used for cleaning the drain tube 3 HC158003BRUSH Double end 1 1 8 inch diameter and 7 16 inch diameter used for clean ing the mix inlet tube mix feed tube head and general cleaning 4 HC196103 BO...

Страница 24: ...For maximum life on moving parts disassemble and sanitize at the end of every day of operation Figure 6 2 continued 1 If there is product in the freezer refer to Section 9 Closing Procedures 9 2 Draining Product 2 Remove plunger rods 6 figure 6 2 by lifting up and swinging the bottom out and down 3 Remove the hand knobs 8 and gently pull the dispensing head 1 straight out 4 Remove the beater shaft...

Страница 25: ...0 plungers 5 3 and nozzles 11 Remove head o rings 2 and the o rings from plungers 4 5 Removehoppercover driptrayand insert 6 Remove the mix feed tube figure 6 4 from the hopper Caution To prevent bacteria growth remove all O rings when cleaning Failure to do so could create a health hazard 7 Remove the O ring 3 from the mix feed tube 1 Remove the regulator 2 from the mix feed tube ...

Страница 26: ...nt sink for washing rinsing and sanitizing parts removed from the freezer per applicable health codes Also prepare a clean surface to air dry all parts Important Do not use unapproved sanitizer or laundry bleach These materials may contain high concentrations of chlo rine bleach and will chemically attack freezer components NOTE The sanitizer should be mixed according to the manufacturer s instruc...

Страница 27: ...a the hoppers and the mix feed tubes from the hopper to the cylinders figure 6 9 b the inside of the cylinders making certain to clean the back walls c the inside of the drain tube figure 6 10 Dip the brush in the dish detergent solution and force brush into the drain tube until it stops repeat until clean 4 Then brush the mix feed tubes cylinders and drain tube with clear water following with san...

Страница 28: ...re than one disconnect switch 1 Persons assembling the freezer must first wash and sanitize their hands and forearms with an approved sani tizer 2 To assemble the shaft seal install the cup seals on the plastic washer Apply a moderate amount of approved sanitary lubricant such as Petrol Gel to the washer Do not allow any lubricant to come in contact with the bell shaped rubber portions of the seal...

Страница 29: ...5 and insert half way into the head 1 9 Install and lubricate the two 4 inch head O rings 2 10 Position the handles in the head assembly by placing the 2 shorter handles 9 on the sides and the long est handle 10 in the center Lock in place with the handle pin 7 Important Excessive force will damage the head Do not use tools to tighten 11 Install the dispensing head onto the freezer by aligning the...

Страница 30: ...sembly 7 Assembly continued 1 Install the o ring on the mix feed tube figure 7 5 Lightly lubricate the o ring Insert the white plastic regulator into the mix feed tube assembly Lift slightly and turn to lock the regulator in the CLOSED see figure 7 6 Figure 7 6 Closed position ...

Страница 31: ...rearms 2 Prepare 2 gallons 7 6 liters of sanitizing solution for each hopper The sanitizing solution must be mixed accord ing to manufacturer s instructions to yield 100 PPM parts per million available chlorine solution example Stera Sheen GreenLabel Usewarmwater 100 110 F or 38 43 C to wash rinse and sanitize Make sure sanitizer is mixed thoroughly and has completely dissolved Important Do not us...

Страница 32: ...heck for leaks around the head plunger and drain tube 8 Place an empty container under the dispensing head and drain the sanitizing solution by opening the plunger to allow cylinder and hopper to empty Open and close the plunger at least 10 times during draining to sanitize the port area of dispense head 9 When the sanitizing solution has drained from the freezer turn the selec tor switch to the O...

Страница 33: ...he white dot on the white plastic tube regulator must be in line with the alignment mark on the metal mix feed tube This is the closed posi tion figure 8 4 3 Place a bucket under the dispense head figure8 5 4 Fill the mix hopper with mix 5 Open the plunger by pulling the dispense handle down Lift the white plastic regulator in the mix feed tube by turning slightly Hold the regulator up When pure m...

Страница 34: ...er the white plastic regulator all the way down in the OPEN position with the smallest black hole aligned figure8 7 Note The largest indent setting will allow the least overrun The smallest indent setting will allow the most air in the cylinder and is used for a higher overrun figure 8 8 7 Place the selector switch to the AUTO position and the DAY NIGHTswitch to DAY 8 Repeat Steps 1 7 for the othe...

Страница 35: ... soap and water Use sanitizing solution in a rinse bottle and brush to clean the bottom of the plunger openings 4 Turn the mix feed regulator to the CLOSED position as shown in figure 9 2 5 Check mix level in hopper to ensure that there is enough mix to keep the indicator light off add mix if necessary Do not dispense product when the mix feed regulator is in the CLOSED position 6 To start the mac...

Страница 36: ...nder the dispensing head and drain the solution by opening the plunger to allow cylinder and hopper to empty 13 When the sanitizing solution has drained from the freezer turn the selector switch to the OFF position 14 Proced to disassemlby cleaning and sanitizing instructions Figure 9 3 Sanitize hopper Note It is your responsibility to be aware of and conform to the requirements for meeting local ...

Страница 37: ...age Weight of liquid mix minus weight of frozen product divided by the frozen weight Multiply by 100 See example Example Weight of 1 pint of mix 18 oz Weight of 1 pint frozen product 12 oz Difference 6 oz 6 oz divided by 12 oz 5 5 x 100 50 overrun Your Electro Freeze Distributor can provide a scale P N HC158049 that is graduated in overrun percentage 10 2 Rerun 4 Once a week run the mix as low as ...

Страница 38: ... surfaces of the freezer to remove any splattered mix 5 Check overrun and temperature of the product Electro Freeze recommends the following schedule to help maintain your freezer in like new operating condition Take the time to learn and perform these routine procedures and receive in return many years of valuable service from your freezer Protect your investment WEEKLY 1 Carefully inspect all pa...

Страница 39: ... CAUTION Moving parts DO NOT place hands in the freezing cylinder Severe personal injury could result 6 Look inside the freezing cylinder toward the rear the drive shaft coupling should NOT be turning Turn the switch OFF and disconnect the main power supply 7 If the drive shaft coupling is turning or you are unable to determine whether or not the shaft is turning turn the switch to the OFF positio...

Страница 40: ...ide panels condenser etc 4 Contact your Electro Freeze Dis tributor to check water cooled condenser and flush clean to remove scale and deposits if necessary SEMIANNUALLY 1 Contact your Electro Freeze distributor to replace drive belts 2 On air cooled and air cooled remote freezers have your Electro Freeze distribu tor check the condenser fan motor oil 2 Have the gear reducer oil changed by your E...

Страница 41: ...enser fins cleaned by an autho rized service technician 7 On water cooled freezers disconnect the water supply Use compressed air to blow out all remaining water in the condenser Important The water valve must be opened in order to blow out the condenser Failure to purge the freezer of water can result in severe damage to the refrigeration system Call your Electro Freeze Distributor for service 8 ...

Страница 42: ...onnected Some freezers have more than one disconnect switch Important Some refrigerants are hazardous to the Earth s atmosphere To protect our environment use a refrigerant recovery recycling unit when removing refrigerant from the system THIS SAFETY ALERT SYMBOL IDENTIFIES IMPORTANT PERSONAL SAFETY MESSAGES IN THIS MANUAL WHEN YOU SEE THIS SYMBOL BE ALERT TO THE POSSIBILITY OF PERSONAL INJURY DO ...

Страница 43: ...ice 6 Faulty selector switch 6 Contact your Electro Freeze distributor for service Unit does not operate 7 Disconnected or broken wire in electrical circuit 7 Contact your Electro Freeze distributor for service Leakage of mix or water from drain tube to drip tray 1 Damaged beater shaft seal or installed improperly 1 Replace cup seals on washer Install properly 2 Beater shaft pitted or damaged 2 Re...

Страница 44: ...inder thermostat erratic or set too cold 1 Contact your Electro Freeze distributor for service 2 Plunger switch electrically or mechanically stuck closed 2 Contact your Electro Freeze distributor for service 3 Faulty time delay Unit runs all the time 3 Contact your Electro Freeze distributor for service Dispensed product too hard 4 Low suction pressure 4 Contact your Electro Freeze distributor for...

Страница 45: ...ompressor and beater motor do not operate when dispensing 1 Plunger switch es defective or out of adjustment 1 Contact your Electro Freeze Distributor for service 2 Time delay defective 2 Contact your Electro Freeze Distributor for service 3 Control relay defective 3 Contact your Electro Freeze Distributor for service 4 Open circuit on HPCO or LPCO 4 Contact your Electro Freeze Distributor for ser...

Страница 46: ...r cleaned by your Electro Freeze distributor lower ambient temperature 2 Thermostat cut in point out of adjustment or malfunctioning 2 Contact your Electro Freeze distributor for service 3 Defective condenser fan motor 3 Contact your Electro Freeze distributor for service Poor or slow product recovery 4 Component or compressor failure 4 Contact your Electro Freeze distributor for service 1 Head as...

Страница 47: ...nked 2 Water turned off or defective water regulating valve water cooled models 2 Turn on water or contact your Electro Freeze Distributor for service 3 Restricted water cooled condenser water cooled models 3 Contact your Electro Freeze Distributor for service 4 Dirty air condenser air cooled models 4 Contact your Electro Freeze Distributor for service 5 Unit location too warm air cooled models 5 ...

Страница 48: ......

Страница 49: ...ted in U S A QUALITY PARTS PROTECT YOUR EQUIPMENT KEEP YOUR FREEZER IN EXCELLENT CONDITION ALWAYS CONTACT YOUR ELECTRO FREEZE DISTRIBUTOR FOR REPLACEMENT PARTS SOFT SERVE FREEZER Model SL500 184599 01 10 13 REPLACEMENT PARTS MANUAL with ILLUSTRATIONS ...

Страница 50: ...one ________________________ If you require any further assistance contact H C Duke Son LLC Electro Freeze as follows Phone 309 755 4553 800 755 4545 FAX 309 755 9858 E mail service electrofreeze com Replacement Parts Orders Table of Contents PART II Figure 1 Head Assembly 1 Figure 2 Beater Shaft Assembly 2 Figure 3 Mix Feed Tube Assembly 3 Figure 4 Switch Box 4 Figure 5 Switch Assemblies 6 Figure...

Страница 51: ...ng Plunger 3 HC160583 O ring Head 4 HC137174 Plunger Side Self Dispense 5 HC138009 Plunger Dispense Center 6 HC113426 Push Rod Assy Plunger Switch 7 HC160269 Pin Handle 8 HC162625 Knob Hand 9 HC120864 Handle Assy Dispense ADA Side HC162629 Knob Ball 3 8 16 THD Black 10 HC120865 Handle Assy Dispense CenterADA HC162629 Knob Ball 3 8 16 THD Black 11 HC196192 Nozzle Serrated Six Point Includes all ite...

Страница 52: ...reezer Use of unapproved parts will void warranty Figure 2 Beater Shaft Assembly Item Part No Description 1 HC139913 Bar Breaker 16 02 in 2 HC120866 Shaft Assy Beater 3 HC141009 Blade Scraper 4 HC160557 Seal Beater Shaft 5 HC137593 Washer Double Shaft Seal Can be ordered together HC115525 Seal Assy Shaft Double ...

Страница 53: ...s with this freezer Use of unapproved parts will void warranty Item Part No Description HC120676 Tube Assy Mix Feed Self Priming Complete 1 HC120672 Tube Assy Mix Feed Self Priming 2 HC137558 Regulator Mix Feed 3 HC160607 O ring Mix Feed Tube Includes all items above Figure 3 Mix Feed Tube Assembly ...

Страница 54: ...ELECTRO FREEZE Soft Serve Model SL500 4 184599 01 Use only original or authorized replacement parts with this freezer Use of unapproved parts will void warranty Figure 4 Switch Box Sheet 1 of 2 ...

Страница 55: ...30V BF25 Compressor 7A HC150082 Coil Contactor 230V BF25 Replacement Not Shown 8 HC150202 Indicator Mix Level 8A HC150540 Light Indicator 230V Not Shown 8B HC150119 Socket Octal Terminal Not Shown 8C HC150120 Clip Retainer Set of 2 Not Shown 9 HC150252 01 Timer 5 45 Delay on Break 230v 10 HC150083 Contactor 230V BF25 Compressor Hopper 10A HC150082 Coil Contactor 230V BF25 Replacement Not Shown 11 ...

Страница 56: ...itch Assy Plunger Center Complete 1 HC114174 Guide Assy Push Rod 2 HC140701 Plate Switch 3 HC150477 Switch Roller Actuator SPDT Side or HC150478 Switch Roller Actuator DPDT Center 4 HC159912 Screw HXHM 1 4 20 x 2 1 4 ZN 5 HC160104 Nut HEX 1 4 20 ZN 6 HC160381 Screw SKHC 6 32 x 1 BKOX 7 HC160393 Washer Flat 6 Brass 8 HC162323 Spring Compression MW ZN LH is left side when facing front of freezer RH ...

Страница 57: ... Drive 1 ea req HC158047 Oil Special Gear Lube Kluber A is left side when facing front of freezer B is right side when facing front of freezer Note To order oil always verify type of oil from the tag located on the gear reducer Improper oil usuage will cause failure and void of warranty HC153367 5 1 Ratio B Side Right Side HC153366 5 1 Ratio A Side Left Side NAMEPLATE GEAR OIL LABEL GEAR OIL LABEL...

Страница 58: ...ELECTRO FREEZE Soft Serve Model SL500 8 184599 01 Use only original or authorized replacement parts with this freezer Use of unapproved parts will void warranty Figure 7 Panel View ...

Страница 59: ...2 in or HC120855 02 Trimstrip Assy EF Decal 22 in Self Serv includes trimstrip and HC164033 03 Decal Trimstrip Self Serv 22 in HC165188 08 Decal Trimstrip EF Logo 22 in 15 HC150540 Light Indicator 230v 16 HC140942 Panel Dispense Not Shown HC162105 Caster 1 1 4 St PT w Brake HC162106 Caster 1 1 4 St PT w o Brake HC150736 Nut Lock Conduit 1 1 4 for Casters HC112978 Leg Assy Six Inch Hardware for Pan...

Страница 60: ...ELECTRO FREEZE Soft Serve Model SL500 10 184599 01 Use only original or authorized replacement parts with this freezer Use of unapproved parts will void warranty Figure 8 Side Rear View Air Cooled ...

Страница 61: ...ed HC150318 Capacitor Run 18 HC151080 01 Motor Fan 35w Enclosed 230 1 60 19 HC159017 Blade Fan 10 in 36 Deg 20 HC120788 Shroud Assy Condenser 21 HC155141 Condenser Air 22 HC153366 Reducer Gear LH 5 1 A side 23 HC153367 Reducer Gear RH 5 1 B side 24 HC111780 Coupling Assy 7 8 Drive 25 HC155071 Receiver 3 lb 3 8 ID Sweat w o valve 26 HC155054 Drier Filter 16 cu in 27 HC153167 Belt V B Side 28 HC1510...

Страница 62: ...ELECTRO FREEZE Soft Serve Model SL500 12 184599 01 Use only original or authorized replacement parts with this freezer Use of unapproved parts will void warranty Figure 9 Side Rear View Water Cooled ...

Страница 63: ...5410 Valve Water 17A HC155444 Kit Water Valve Repair 18 Box Assy Capacitor 1 ph Beater Motor HC119912 Cap Assy w Bleed HC150318 Capacitor Run 19 HC155029 Condenser Water 20 HC151017 Motor Fan 5 Watt 230V 21 HC159032 Blade Fan 6 20 22 HC120151 Shroud Assy Condenser 23 HC155139 Condenser Air 8x8 24 HC153366 Reducer Gear LH 5 1 A side 25 HC153367 Reducer Gear RH 5 1 B side 26 HC111780 Coupling Assy 7...

Страница 64: ... brake HC184233 Chart O ring EF Gravity SS Laminated HC120858 Cover Assy Control Switch 22 in Open HC196111 Cover Hopper HC158012 Handle Brush Fiberglass Brush p n HC158009 HC115536 Kit O ring HC158054A Lubricant Lubri Film Plus 4 oz tube HC158000A Lubricant Petro Gel 4 oz tube HC112978 Leg Assy Six inch Optional HC196185 Nozzle Serrated HC150736 Nut Lock Conduit 1 1 4 Casters HC158013 Sanitizer S...

Страница 65: ...ELECTRO FREEZE Soft Serve Model SL500 184599 01 15 Use only original or authorized replacement parts with this freezer Use of unapproved parts will void warranty ...

Страница 66: ......

Страница 67: ... HC153167 2 D2P 908 Blade Fan 10 36 Air Cooled HC159017 2 D2P 908 Blade Fan 6 20 Water Cooled HC159032 1 D2P 908 Blade Scraper HC141009 4 D2P 908 Bottle Wash 500 ml HC196103 1 D2P 908 Brush 4 in w o handle Handle p n HC158012 HC158009 1 D2P 908 Brush 7 16 1 1 8 Double End HC158003 1 D2P 908 Brush 9 16 in w 36 in handle HC158077 1 D2P 908 Capacitor Assy w resistor Start Beater Motor HC119912 1 D2P ...

Страница 68: ...P 908 Valve Access HC155419 1 D2P 908 Valve Core HC155649 1 D2P 908 Compressor Assy 208 230 3 60 3 ph HC119541 1 D2P 908 Drier Filter 16 cu in HC155054 1 D2P 908 Grommet Compressor Mounting HC151478 4 D2P 908 Sleeve Compressor Mounting HC151479 4 D2P 908 Valve Access HC155419 1 D2P 908 Valve Core HC155649 1 D2P 908 Compressor Kit Hopper HC120927 1 D2P 908 Drier Fitler HC155498 1 D2P 908 Condenser ...

Страница 69: ...P 908 Cut Out High Pressure 450 PSI Air Cooled HC155450 1 D2P 908 Cut Out Low Pressure HC155701 1 D2P 908 Cylinder Assy Complete HC115467 01 1 D2P 908 Decal Beater Installation HC164034 1 D2P 908 Decal Beater Warning HC165025 1 D2P 908 Decal Cleaning Instructions HC165234 1 D2P 908 Decal Clear Overlay HC165093 1 D2P 908 Decal Operating Instructions HC164004 03 1 D2P 908 Decal Panel Removal HC16512...

Страница 70: ...08 Knob Ball 3 8 16 THD Black HC162629 1 D2P 908 Handle Brush Fiberglass Brush p n HC158009 HC158012 1 D2P 908 Head Assy Dispense HC114995 1 D2P 908 L2P 4129 Head Assy w actuators Head only HC116301 1 D2P 908 L2P 4129 Handle Assy Dispense Side HC110007 2 D2P 908 L2P 4129 Handle Assy Dispense Center HC114808 1 D2P 908 L2P 4129 Nozzle Serrated HC196185 3 D2P 908 L2P 4129 O ring Plunger HC160501 8 D2...

Страница 71: ...5 1 A2Q 262 Nozzle Serrated Six Point HC196192 3 A2Q 262 O ring Plunger HC160501 8 A2Q 262 O ring Head HC160583 2 A2Q 262 Pin Handle HC160269 1 A2Q 262 Plunger Dispense Center HC138009 1 A2Q 262 Plunger Side Self Dispense HC137174 2 A2Q 262 Indicator Mix Level HC150202 2 D2P 908 Insert Assy Drip Tray HC120778 1 D2P 908 Insulator Expansion Valve HC165531 2 D2P 908 Jumper 2 Circuit Elec Temperature ...

Страница 72: ...80 01 2 D2P 908 Motor Fan 5 Watt 230v Water Cooled HC151017 1 D2P 908 MOV Assy Electric Box HC116188 2 D2P 908 Nozzle Serrated HC196185 3 D2P 908 L2P 4129 Nozzle Serrated Serial No L2P 4129 to A2O 261 Could be either HC196185 or HC196192 HC196192 has 6 points Nozzle Serrated Six Point HC196192 3 A2O 262 Nut HEX 1 4 20 ZN SwitchAssy HC160104 1 D2P 908 Nut Lock Conduit 1 1 4 Casters HC150736 4 D2P 9...

Страница 73: ...HC114174 1 D2P 908 Nut HEX 1 4 20 ZN HC160104 1 D2P 908 Screw HXHM 1 4 20 x 2 ZN HC160104 1 D2P 908 Spring Compression MW ZN HC162323 1 D2P 908 Switch Roller Actuator DPDT HC150478 1 D2P 908 Plunger Side Self Dispense HC137174 2 D2P 908 Guide Assy Push Rod HC114174 2 D2P 908 Nut HEX 1 4 20 ZN HC160104 2 D2P 908 Screw HXHM 1 4 20 x 2 ZN HC160104 2 D2P 908 Spring Compression MW ZN HC162323 2 D2P 908...

Страница 74: ... 1 4 20 x 2 1 4 ZN SwitchAssy HC159912 3 A2Q Screw SK Set 1 4 20 x 1 4 HC160495 4 D2P 908 Screw SK Set 5 16 18 x 3 8 HC160033 4 D2P 908 Screw SKHC 6 32 x 1 BKOX Switch Assy HC160381 6 D2P 908 Screw TRPM 1 4 20x1 SST Side Panel HC159219 D2P 908 Screw TRPM 1 4 20x1 2 SST Rear Panel HC160048 D2P 908 Screw TRPM 10 24x1 2 SST Front Dispense Trimstrip Panels HC160076 D2P 908 Seal Assy Shaft Double HC115...

Страница 75: ... 1 D2P 908 Switch Roller Actuator DPDT HC150478 1 D2P 908 Washer Flat 6 Brass HC160393 2 D2P 908 Switch Assy Plunger Side LH HC118095 2 D2P 908 Guide Assy Push Rod HC114174 2 D2P 908 Nut HEX 1 4 20 ZN HC160104 2 D2P 908 Plate Switch HC140701 2 D2P 908 Screw HXHM 1 4 20 x 2 ZN HC160066 2 D2P 908 A2Q Screw HXHM 1 4 20 x 2 1 4 ZN HC159912 2 A2Q Screw SKHC 6 32 x 1 BKOX HC160381 4 D2P 908 Spring Compr...

Страница 76: ... HC150252 01 4 D2P 908 Timer 5 Minute NLU HC150218 2 D2P 908 K2P Tool O ring Removal HC169374 1 D2P 908 Tray Drip 22 in Black HC196270 1 D2P 908 Trimstrip Assy EF Decal 22 in HC120855 1 D2P 908 B2Q Decal Trimstrip EF Logo 22 HC165188 08 1 D2P 908 Trimstrip Assy EF Decal 22 in Self Serve HC120855 02 1 Optional Decal Trimstrip Self Serv 22 in HC164033 03 1 Optional Decal Trimstrip EF Logo 22 HC16518...

Страница 77: ...IAL NUMBER DESCRIPTION NUMBER QTY FROM TO Use only original or authorized replacement parts with this freezer Use of unapproved parts will void warranty Valve Solenoid Cylinder NLU Use HC155395 and HC151477 HC155488 2 D2P 908 Valve Solenoid Body 3 8 ODM Cylinder Use with coil HC151477 HC155395 2 D2Q Valve Solenoid 208 240v Hopper NLU Use HC155394 and HC151477 HC155707 2 D2P 908 Valve Solenoid Body...