ELECTRO FREEZE Soft Serve Model SL500
34
184599
12
Trouble Shooting Tables
(continued)
1.
Freezer unplugged.
1. Plug in freezer.
2.
Fuse or breaker blown at main
disconnect.
2. Make sure your freezer is connected to a
separate circuit independent from any
other electrical equipment. Have
technician check fuse or breaker size and
check voltage; if not within 10% of
nameplate rating call power company.
3.
Beater motor out on overload.
3. Press overload reset button. Check
product temperature an overrun.
4.
Off on high pressure cut-out control.
4. Refer to Troubleshooting Table –
Discharge pressure too high.
5.
Off on low pressure cut-out control.
5. Contact your Electro Freeze distributor for
service.
6.
Faulty selector switch.
6. Contact your Electro Freeze distributor for
service.
Unit does not
operate.
7.
Disconnected or broken wire in electrical
circuit.
7. Contact your Electro Freeze distributor for
service.
Leakage of mix
or w ater from
drain tube to drip
tray.
1.
Damaged beater shaft seal or installed
improperly.
1.
Replace cup seals on washer. Install
properly.
2.
Beater shaft pitted or damaged.
2.
Replace beater shaft.
3.
Beater shaft end play not set properly.
3.
Contact your Electro Freeze distributor for
service.
1.
Faulty head o-ring.
1. Replace o-ring.
2.
Head not properly installed.
2. Install head properly. Replace o-ring if
pinched.
3.
Faulty contactor.
3. Contact your Electro Freeze Distributor for
service.
Compressor
does not operate
or operates
improperly.
4.
Disconnected or broken wire in switch.
4. Contact your Electro Freeze Distributor for
service.
PROBLEM
PROBABLE
CAUSE
REMEDY