32
184599
ELECTRO FREEZE Soft Serve Model SL500
WINTER STORAGE
To protect the unit during seasonal shutdown, it is important to store the freezer
properly. Use the following procedures:
1. Disconnect all power to the freezer.
2. Disassemble and wash all parts that come into contact with the mix using
a warm, mild detergent solution. Rinse in clear water and air dry all parts thoroughly.
Clean drain tube and all exterior panels.
3. Store the loose parts, such as the head assembly and beater assembly, in
a safe dry place.
4. Do not lay heavy objects on the plastic or rubber parts.
5. Cover the freezer and all loose parts to protect them from dust or other
elements that could contaminate them while in storage. Place the freezer in a dry
location.
6. If you have an air cooled freezer, have condenser fins cleaned by an autho-
rized service technician.
7. On water-cooled freezers, disconnect the water supply. Use compressed
air to blow out all remaining water in the condenser.
Important:
The water valve must be opened in order to blow out the condenser. Failure to
purge the freezer of water can result in severe damage to the refrigeration
system. Call your Electro Freeze Distributor for service.
8. When freezer is restarted after seasonal shutdown, remember to replace all
o-rings and seals with new parts. Rubber parts can lose their elasticity and ability to
seal when stored.
11
ROUTINE MAINTENANCE
USE ONLY ORIGINAL OR AUTHORIZED REPLACEMENT PARTS WITH THIS FREEZER.
If you have any questions on items that are not included in this schedule or problems that require
service assistance, please call your local distributor or H.C. Duke & Son, LLC,
Electro Freeze
,
Service Department for factory service assistance.
Phone: (309) 755-4553 or (800) 755-4545
FAX: (309) 755-9858.