63
Error Message List
* = See module de -installation instructions on pre vious page .
Error Msg
Problem
Troubleshooting ste ps
ERR 12V
The
circuit bre aker
on the KPA3 module may
be open. PA drops into bypass mode, fans
switch to level 2, and PA temp display mode is
not available.
Check
f
or
s
hor
t
f
r
om
PA
modul
e’
s
12V
l
i
ne
t
o
gr
ound.
I
f
t
he
r
e’
s
no
s
hor
t
,
t
r
y
resetting the circuit breaker. If there is a
short, remove the KPA3 module. Set
CONFIG:KPA3
to
P AIO NO R
. While
waiting for a replacement, you can use the
K3 at reduced power.
ERR AT3
KAT3 not responding
*
De -install
the KAT3 module (see above).
If this eliminates the error message, the
KAT3 may be defective. You can
substitute a KANT 3 antenna input module
temporarily, if available.
ERR BP1
No response from RF board BPF shift registers
*
De -install
option modules one at a time
ERR BP2
No response from KBPF3 option shift registers
*
De -install
KBPF3 on RF board
ERR BP3
No response from sub RX BPF shift registers
*
De -install
the KRX3 module, including
the SUBIN and SUBOUT boards
ERR BP4
No response from sub RX KBPF3 option
*
De -install
the KBPF3 module on KRX3
ERR DS1
No main DSP SPI echo
Reload DSP1 firmware
ERR DS2
Main DSP SPI echo not inverted
Reload DSP1 firmware
ERR DS3
No AUX DSP SPI echo
Reload DSP2 firmware. Note:
CONFIG:KRX3
must be set to
NO T
I NS T
unless the KRX3 option is installed,
which includes the aux DSP module
(DSP2) and 2
nd
synthesizer.
ERR DS4
AUX DSP SPI echo not inverted
Reload DSP2 firmware. Note:
CONFIG:KRX3
must be set to
NO T
I NS T
unless the KRX3 option is installed,
which includes the aux DSP module and
2
nd
synthesizer.
ERR DSE
Missing echo from a DSP command
Reload DSP1 firmware (and DSP2
firmware, if applicable).
ERR DSX
Extended DSP command timeout
Reload DSP1 firmware (and DSP2
firmware, if applicable).
ERR EE1
On-chip EEPROM read/write test failed
MCU may be defective (front panel). T ry
re-loading MCU firmware first;then try
initializing parameters (pg. 61).
ERR EE2
External EEPROM read/write test failed
EEPROM may be defective (front panel).
However, this message may also appear if
power is turned off/on too rapidly, or if the
power
s
uppl
y
vol
t
age
“bounces
”
dur
i
ng
turn-on due to inadequate regulation. If the
power supply is not at fault, try re-loading
MCU firmware first;then try initializing
parameters (pg. 61).
ERR FW2
General firmware problem
Try re-loading MCU firmware first; then
try initializing parameters (pg. 61).