52
CONFIG Menu
Tech Mode Entries
Menu entries that include
[T]
are
tech mode
entries. These are only visible if
CONFIG:TECH MD
is set to
O N
.
They
ar
e
nor
mal
l
y
l
ef
t
a
t
t
hei
r
def
aul
t
s
.
Ent
r
i
es
f
ur
t
he
r
des
cr
i
bed
as
“
Advance d
”
or
“
Troubleshooting
”
s
houl
d
be changed with caution. The default values are strongly recommended for these functions; tap
D I S P
to see the
default value, which appears in parentheses at the start of the help text.
Sub Receiver Settings
Menu entries marked
SUB
have two settings: one for the main receiver, and one for the sub receiver. If a sub
receiver is installed, the menu entries will change to identify which receiver is being set up by showing
RF
(main receiver) or
S UB
(sub receiver) at the left end of the parameter display. Also, in the
S UB
case, the
SUB
icon will flash.
Prior to adjusting sub receiver menu parameters, you should turn the sub receiver on by tapping
S UB
. This is
es
peci
al
l
y
i
mpor
t
a
nt
i
f
you’
r
e
adj
us
t
i
ng
cr
ys
t
al
f
i
l
t
er
s
et
t
i
ngs
,
becaus
e
i
t
wi
l
l
al
l
ow
you
t
o
hear
t
he
cha
nges
as
filters are selected and modified. You should also turn SUB AF gain up and main AF gain down.
Even if the sub receiver is turned on, when you first enter the menu,
RF
will be in effect, and the
SUB
icon will
be turned off. T ap
S UB
to switch to the sub receiver parameter as required.
Entry
Default
Description
2 T ONE
[T]
OFF
(Troubleshooting.)
Enables built-in 2-tone generator for SSB transmit tests. The
internal 2-tone generator only works if LSB or USB mode is selected. After
setting 2-tone ON, exit the menu and tap XMIT . You can use
MI C
to to adjust
the amplitude of one of the ton
es
;
t
he
ot
he
r
’
s
ampl
i
t
ude
i
s
f
i
xed.
AF GAIN
HI
Sets AF gain range. Available selections are
HI
or
LO
.
AFV T IM
[T]
1000
(Advance d.)
Integration time for
AFV
and
dBV
displays in ms. See VFO B
alternate display information (pg. 36).
AGC HLD
[T]
0
(Advance d.)
AGC
“hol
d”
t
i
me
f
or
voi
ce
modes
.
Speci
f
i
es
t
he
number
of
milliseconds that the SLOW AGC value is held after the signal drops below the
level that set the AGC. This is often helpful for SSB voice operation.
AGC PLS
[ T]
NOR
(Advance d.)
NO R
enables AGC noise pulse rejection.
AGC SLP
[T]
12
(Advance d.)
Hi
ghe
r
val
ues
r
es
ul
t
i
n
‘
f
l
a
t
t
e
r
’
AGC
(
ma
ki
ng
s
i
gnal
s
at
al
l
amplitudes closer in AF output level).
AGC T HR
[T]
5
(Advance d.)
Sets AGC onset point; a higher number moves the onset up.
AGC-F
[ T]
120
(Advance d.)
Sets fast AGC decay rate; a higher number means faster decay.
AGC- S
[ T]
20
(Advance d.)
Sets slow AGC decay rate; a higher number means faster decay.
AUT OINF
[T]
NOR
(Advance d.)
If set to
AUTO 1
, the K3 will send band data on its RS232 port for
us
e
wi
t
h
devi
ces
s
uch
as
t
he
St
eppI
R™
a
nt
enna
on
e
ver
y
band
c
hange.
(
Not
e:
This setting may not be compatible with PC software applications that use the
“AI
”
r
e
mot
e
cont
r
ol
command.)
BAT MIN
11.0
Low-battery warning threshold;
1 1 .0
recommended. If the voltage drops below
this level, the operator will be alerted with a
BAT LO W
message. The menu
parameter flashes if this occurs within the menu, so the level can be easily tested.