50
Front Panel Temperature Sensor
T urn the K3 OFF. Allow about 15 minutes for
the radio to cool to room temperature.
T urn the K3 ON.
Locate the
CONFIG:FP TEMP
menu entry.
Adjust the parameter to match the reading of a
room thermometer.
Note:
Deg. C = (deg.
Fahrenheit - 32) * 0.555.
Front panel compartment temperature can be
monitored continuously. T ap
DI S P
, then use VFO
B to select the
FP xx C
alternate display.
PA Temperature Sensor
T urn the K3 OFF. Allow about 15 minutes for
the PA heatsink to coolto room temperature.
Do not turn the K3 ON during this pe riod.
T urn the K3 ON.
Locate the
CONFIG:PA TEMP
menu entry.
Adjust the parameter to match the reading of a
room thermometer.
Note:
Deg. C = (deg.
Fahrenheit - 32) * 0.555.
PA heat sink temperature can be monitored
continuously. T ap
DI S P
, then use VFO B to select
the
P A x x C
alternate display.
S-Meter
S-meter calibration is normally adequate using the
default settings for both the main and sub receivers.
Calibrating the S-meter requires a 50-ohm, 50-
microvolt signal (an accurate signal generator such
as an Elecraft XG1 or XG2 is recommended).
I
f
you’
r
e
cal
i
br
at
i
ng
t
he
s
ub
r
ecei
ver
’
s
S
-meter:
(1) tap
SU B
to turn the sub receiver on; (2)
hold
B S E T
to gain access to sub receiver
controls; (3) tap
AN T
until you see
M AI N
flashed on VFO B; this sets up the sub receiver
to share the main RF path (pg. 37).
Switch to a band applicable to your signal
generator and select CW mode.
Se t transmit powe r to 0.0 W
using
P W R
.
T urn preamp on (
P R E
), attenuator off (
AT T
).
T ap
AG C
to select slow AGC (
AG C-S
).
Bypass the ATU, if installed, by holding
ATU
.
Set
RF GAIN to maximum (
fully
clockwise)
. (
Note:
I
f
you’
ve
as
s
i
gned
t
he
RF
gain control for the present receiver to
squelch
,
its RF gain will default to maximum unless
you’
r
e
cont
r
ol
l
i
ng
RF
gai
n
f
r
om
a
r
e
mot
e
-
control computer application.)
Normalize the DSP filtering (hold
N OR M
; pg.
14).
Connect the signal generator to ANT1 and set it
for 50 microvolts RF output.
T une to the frequency of the signal generator
(tune for peak audio response). You can also
use
auto-spot
(pg. 30) to accurately match the
pitch of the signal, ensuring that it is centered in
the passband.
The S-meter has both relative and absolute
modes. Refer to the
CONFIG:SMTR MD
menu entry description if you wish to switch
from relative to absolute. (Relative mode is
easier to calibrate and is the factory default.)
Locate the
CONFIG:SMTR PK
menu entry;
set it to
O FF
.
Locate the
SMTR SC
menu entry (S-meter
scale). Use the VFO A knob to set it to the
default value (14).
Adjust
SMTR OF
(S-meter offset) for an S-9
reading.
Switch the signal generator to 1-
µ
V output; the
S-meter should now indicate about S-2 to S-3.
If not, change
SMTR SC
by 1 unit (try 15 first,
then 13, then 16, then 12). After each
SMTR
SC
change, re-adjust the
SMTR OF
setting for
an S-9 indication.
When you have completed this procedure,
disconnecting the signal generator should now
show NO bars on the S-meter.