8
2. Technical Specifications
2.1 Electrical & Mechanical Characteristics
Electrical & Mechanical Characteristics
Main Power Supply
16-24V 50 Hz ~1.5A max / 18-24V
1,5A max
Current in Standby without External Sensors and Keyboard
Up to 80mA
Recommended Backup Battery Voltage, Capacity
12V; 1,3-7Ah
Recommended Backup Battery Type
Lead-Acid
Maximum Battery Charge Current
900mA
GSM Modem Frequency
850/900/1800/1900MHz
Cable Type for GSM Antenna Connection
Shielded
Number of Zones on Board
6 (ATZ mode: 12)
Nominal Zone Resistance
5,6kΩ (ATZ Mode: 5,6kΩ and 3,3kΩ)
Number of PGM Outputs on Board
4
ESIM364 PGM Output Circuit
Maximum Commuting PGM Output Values
Voltage – 30V; Current – 100mA;
BELL: Siren Output when Activated
Connected to COM
BELL: Maximum Siren Output Current
1A
BELL: Maximum Cable Length for Siren Connection
up to 30 meters
BELL: Cable Type for Siren Connection
Unshielded
AUX: Auxiliary Equipment Power Supply Voltage
13,8V DC
AUX: Maximum Accumulative Current of Auxiliary Equipment
1,1A
AUX: Maximum Cable Length for Auxiliary Equipment Connection
up to 100 meters
AUX: Cable Type for Auxiliary Equipment Connection
Unshielded
BUZ: Maximum Current of Mini Buzzer
150mA
BUZ: Power Supply Voltage of Mini Buzzer
5V DC
BUZ: Cable Type for Mini Buzzer Connection
Unshielded
Dimensions
140x100x18mm
Operating Temperature Range
20...+55
0
C
Supported Temperature Sensor Model
Maxim®/Dallas® DS18S20, DS18B20
Maximum Supported Number of Temperature Sensors
8
DATA: Maximum Cable Length for 1-Wire® Communication
up to 30 meters
DATA: Cable Type for 1-Wire® Communication
Unshielded
Supported iButton® Key Model
Maxim®/Dallas® DS1990A
Maximum Supported Number of Keyboards
4 x EKB2 / EKB3
Y/G: Maximum Cable Length for RS485 Communication
up to 100 meters
Y/G: Cable Type for RS485 Communication
Unshielded
MIC: Maximum Cable Length for Microphone Connection
Up to 2 meters
MIC: Cable Type for Microphone Connection
Unshielded
Wireless Transmitter-Receiver Frequency
868 Mhz
Wireless Communication Range
Up to 30m in premises; up to 150m in open areas
Maximum Supported Number of Wireless Devices
32
Event Log Size
500 events
Maximum Supported Number of Zones
76
Maximum Supported Number of PGM Outputs
76
Cable Type for Zone and PGM Output Connection
Unshielded
Communications
SMS, Voice calls, GPRS network, RS485, CSD, PSTN
Supported Protocols
Ademco Contact ID®, 4+2, EGR100, Kronos, Cortex®
1 R
OUT
Open Collector Output.
Output is pulled to COM
when turned ON.