MANUAL ELDES ESIM364 V1.2
19
3.3 Activating STAY Mode
NOTE:
Delay Zone
Becomes Instant in
Stay
Mode
feature may be enabled on your system. In that case the alarm will be
caused instantly instead of entry delay
countdown being initiated if a delay zone becomes violated while the system
is operating in Stay mode. For more details, please, contact your alarm system installer.
3.3.1 Arm by EKB2 Keypad in STAY Mode Manually
EWK1
EKB2
EKB2
EKB3
Stay mode allows the user to remain in the secured area after arming the system. In Stay mode, the system does not
cause the alarm when the zones, set up to operate under this mode, become violated. This mode is usually used
when arming the system before night.
There are two ways to activate Stay mode:
•
Automatic
- This mode is activated automatically in case the user does not leave the secured area (if delay zone
is not violated and restored) during exit delay countdown when arming the system.
•
Manual
- The system goes into Stay mode after the user opens an additional menu or presses [STAY] key and
enters a valid user password by EKB2 and EKB3/EKB3W keypad respectively.
There is no exit delay countdown when activating Stay mode manually.
Stay
mode status is indicated in the home screen view of EKB2.
Stay mode is NOT activated when arming the system by phone call or SMS text message.
1. Navigate through the following menu path using P2 and arrow keys and enter a valid user password using the
number keys to arm the system in Stay mode manually:
Menu path:
If only 1 partition is enabled:
P2
→
uuuu
→
OK
If more than 1 partition is enabled:
P2
→
uuuu
→
OK
→
[p] partname
→
OK
Value:
uuuu
4digit user password
2. When the system is successfully armed, it will reply with confirmation by SMS text message to User 1 phone
number (by default).
For more details on how to disarm & turn off the alarm by EKB2 keypad, please refer to chapter
3.2.5 Disarm & Turn off
the Alarm by EKB2 Keypad
.
User
ESIM364
SMS
Fig. No. 24