MANUAL ELDES ESIM364 V1.2
7
1.3 EKB3/EKB3W Keypad Overview
EKB3/EKB3W is a LED keypad intended for using with ESIM364 alarm system.
1
2
3
4
5
6
7
ARMED
READY
SYSTEM
BYPS
A
B
1
2
3
4
5
6
7
8
9
10
11
12
8
9
*
0
#
STAY
BYPS
INST
CODE
LED Functionality
ARMED
Alarm system is armed /Configuration mode
READY
System is prepared for arming
SYSTEM
System faults / valid command is being entered
BYPS
Zone bypass mode
112
Violated zone
Keys Functionality
[BYPS]
Zone bypass mode
[CODE]
Additional options - system fault list / violated high zone indication / violated tamper indication
[*]
Configuration Mode (when typed as a 1st character) / cancel command (when typed as a 2nd character) / keypad
partition switch (if enabled)
[#]
Confirm (enter) command
[0] ... [9]
Command typing
[STAY]
Manual Stay mode activation
[INST]
(currently inactive)
The green indicator
READY
indicates that no zones are violated or no faults are present and the system is prepared for arming. Yellow
indicator
SYSTEM
lights up or flashes in case of zone violation or if system faults are present. The alarm system cannot be armed until
the faults are removed or violated zone (-s) is restored, bypassed or set up to operate under Force mode. The following faults allow
system arming when present:
•
main power supply is lost.
•
low battery.
•
battery dead or missing.
•
battery failed.
•
siren failed.
•
GSM jammer detected.
•
date/time not set.
•
GSM connection failed.
•
GSM antenna failed.
Audio Indication
The built-in buzzer uses two types of sound signals – three short beeps and one long beep. Three short beeps stand for successfully
carried out configuration command, one long beep – for invalid configuration command. In addition, the buzzer emits short beeps
in case of alarm.
Visual Indication
EKB3 keys have a LED back-light, therefore it is possible to use this keypad even in dark premises. The back-light lasts for 3 minutes
after the last key-stroke while the system is disarmed. In case of alarm, the keypad back-light turns ON and lasts until the system is
disarmed.
EKB3W keys have a LED back-light, which will be activated once any key is pressed. Due to battery power saving reasons, the back-
light and LED light last for 10 seconds after the last key-stroke.
1.4 Partitions
Your alarm system may be divided into up to 4 partitions: Partition 1 - Partition 4 . Each system partition operates independently
from each other, therefore dividing the system into partitions allows to use 1 alarm system unit to secure up to 4 different areas, for
example: office and warehouse, house and garage etc. By default configuration, the system is NOT divided into partitions and all user
phone numbers, user passwords, keypads, iButton® keys, zones are assigned to Partition 1.
Fig. No. 2