User Manual v1.2
Valid for ESIM364 v02.04.01 and up
Safety instructions
Please read and follow these safety guidelines in order to maintain safety of operators and people around:
• GSM alarm & management system ESIM364 (also referenced as alarm system, system or device) has radio transceiver operat
ing in GSM 850/900/1800/1900 bands.
• DO NOT use the system where it can be interfere with other devices and cause any potential danger.
• DO NOT use the system with medical devices.
• DO NOT use the system in hazardous environment.
• DO NOT expose the system to high humidity, chemical environment or mechanical impacts.
• DO NOT attempt to personally repair the system.
• System label is on the bottom side of the device.
GSM alarm system ESIM364 is a device mounted in limited access areas. Any system repairs must be done only by quali
fied, safety aware personnel.
The system must be powered by main 16-24V 50 Hz ~1.5A max or 18-24V
1,5A max DC power supply which must
be approved by LST EN 60950-1 standard and be easily accessible nearby the device. When connecting the power supply
to the system, switching the pole terminals places does not have any affect.
Any additional devices linked to the system ESIM364 (computer, sensors, relays etc.) must be approved by LST EN 60950-1
standard.
Main power supply can be connected to AC mains only inside installation room with
automatic 2-pole circuit breaker capable of disconnecting circuit in the event of short
circuit or over-current condition. Open circuit breaker must have a gap between con
nections of more than 3mm and the disconnection current 5A.
Mains power and backup battery must be disconnected before any installation or tuning work starts. The system installa
tion or maintenance must not be done during stormy conditions.
Backup battery must be connected via the connection which in the case of breaking would result in disconnection of one
of battery pole terminals. Special care must be taken when connecting positive and negative battery terminals. Switching
the pole terminals places is NOT allowed.
In order to avoid fire or explosion hazards the system must be used only with approved backup battery.
The device is fully turned off by disconnecting 2-pole switch off device of the main power supply and disconnecting
backup battery connector.
Fuse F1 type – Slow Blown 3A. Replacement fuses have to be exactly the same as indicated by the manufacturer.
If you use I security class computer for setting the parameters it must be connected to earth.
Phase
AC 230V
50 Hz/DC 24V
USB cable
Null
PE
ESIM364
AC/DC
The WEEE (Waste Electrical and Electronic Equipment) marking on this product (see left) or its documentation indicates that the
product must not be disposed of together with household waste. To prevent possible harm to human health and/or the environ
ment, the product must be disposed on in an approved and environmentally safe recycling process. For further information on how
to dispose of this product correctly, contact the system supplier, or the local authority responsible for waste disposal in your area.