USER MANUAL ELDES ESIM252 V1.0
23
FOR ADVANCED USERS
All these features can be configured using program “ELDES Configuration Tool“
As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful
delivery of the SMS message, it is necessary to remove users NO1 and NO3 and disable alarm calls for all users. It is also necessary to
enable impulse counting mode for Esim252 input Z3 and set the number of expected impulses.
a) First of all a signal indicating PUMP triggering is connected to Esim252 input Z3.
b) The following configuration SMS message must be sent to Esim252 system:
where SC13 means that alarm SMS message sending is disabled for users NO1, NO3 after input Z3 zone violation.
CC123 means that alarm calls are disabled for users NO1, NO2 and NO3 after input Z3 violation.
We make an assumption that users NO4-NO5 were not entered to the system at all.
IE1 enables impulse counting mode for input Z3. IC10 means that the alarm is given to input Z3 after 10 impulses are transmitted.
Task No2:
Configuring the system so that the operating personnel member (NO2) receives SMS message if the pump‘s input was violated for
10 times.
XXXX_SMSEXTRA:Z3:SC13,CC123,IE1,IC10