28
Type of control
via call
MS
1,2,3,4,5 and 0
When users
No:1,2,3,4,5 call the
output is turned on.
The first digit refer to user number. The second
digit refers to command. Therefore to set a
possibility for user NO1 to turn on the output via
call you have to use the command MS10
1,2,3,4,5 and 1
When users
No:1,2,3,4,5 call the
output is turned off.
MS11
The first digit refer to user number. The second
digit refers to command. Therefore to set a
possibility for user NO1 to turn off the output via
call you have to use the command MS11
1,2,3,4,5 and 2
When users
No:1,2,3,4,5 call
output status is
changed (TOGGLE)
The first digits refer to user number. The last digit
refers to command. Therefore to set a possibility
for user NO1 to turn on the output by one call and
then disable it by the next call you have to se the
command MS12
Setting relay
impulse
duration
MS
1,2,3,4,5 and
Th.m.s
Setting output
impulse duration for
users No:1,2,3,4,5.
h- hours, m- minutes,
seconds.
E. g. to set the timer for 5 hours 10mins 3seconds
for user NO1 you have to use the command
MS1T5.10.3
This means that when afore mentioned user NO1
control the output via call the impulse duration is
5hours 10mins and 3seconds and after this period
the output returns to the previous state
Example of SMS message configuring C1 output:
This message configures C1 output parameters.
CE1234 means that С1 output can be controlled by users NO1-NO4 (NO5 cannot control via call).
CS123 means that only users NO1, NO2 and NO3 will receive confirmation call.
MS10 means that when user NO1 calls the system he/she enables C1 input, but cannot disable it via call. The user can disable it via
SMS message if he/she knows the password.
MS42 means that when user NO4 calls the system he/she will either enable or disable output C1 (TOGGLE mode is on). It depends
on the output status before making a call.
MS1T0.0.40 means that when user NO1 make a call to the system, the output is turned on for 40seconds and then it automatically turns off.
To see the preset values for any command send SMS message with the same format that you use when changing parameters; only
Value structure will have no value. This does not apply to MS and CT commands. When requesting MS and CT parameters MS and
CT must be followed by one character – user number (1,2,3,4 or 5).:
XXXX – user password. COCx - output control by call; value can be COC1 (C1 output) or COC2 (C2 output). ValueN structure is CnVal,
when Cn is command name ((2 letters). This does not apply to MS and CT commands. When requesting MS and CT parameters MS
and CT must be followed by one character – user number (1,2,3,4 or 5).
E. g. XXXX_SMSEXTRA:COC1:CE,CS,MS1,MS3
3.9.2.2 Settings of the output controlled by SMS messages
This chapter describes the ways of informing users when they are trying to open/close the relay output (-s) via SMS messages des-
cribed in chapter 3.6. Parameters are changed by sending the following SMS message to system ESIM252:
XXXX – user password. OCSx - output control by SMS; value can be OCS1 (C1 output) or OCS2 (C2 output). Value structure is CnVal,
where Cn is command name (2 letters), and Val-its value (digits without spaces or punctuation marks).
XXXX_SMSEXTRA:COC1:CE1234,CS123,MS10,MS42,MS1T0.0.40
XXXX_SMSEXTRA:COCx:Value1,Value2,……,ValueN
XXXX_SMSEXTRA:OCSx:Value1,Value2,……,ValueN
FOR ADVANCED USERS
All these features can be configured using program “ELDES Configuration Tool“
Содержание ESIM252
Страница 1: ...GSM CONTROL SYSTEM ESIM252 ...
Страница 33: ...USER MANUAL ELDES ESIM252 V1 0 33 ...
Страница 34: ...34 For notes ...
Страница 35: ...USER MANUAL ELDES ESIM252 V1 0 35 For notes ...
Страница 36: ...Made in Lithuania www eldes lt ...