FOR ADVANCED USERS
All these features can be configured using program “ELDES Configuration Tool“
E. g. 3.
The user wants to connect Esim252 system to the heating system of the house.
As per factory default settings C1 output control via calls is disabled for all users, it is necessary to enable this feature and to set the
users who will be able to control the output – in this case it is user NO1. Besides it is also necessary to set output status for user NO1
when he/she calls the system. In this case you must set the system so that the output is turned on after one call and turned off after
another one (Toggle) and so on. User NO1 needs to enable confirmation call (Call Back) feature and set the length parameters for
that call. To differentiate whether the output was turned on confirmation call will be set to ring for 3 seconds and the confirmation
call will ring for 10 seconds when the output was turned off.
a) First of all ESIM252 system output C1 has to be connected to the connectors of heating controller unit.
b) The following configuration SMS message must be sent to Esim252 system:
where COC1 means C1 output control by call is enabled for users NO1.
CS1 means that confirmation call feature is enabled for user NO1 after output C1 status changes.
CT113 means that user NO1 will receive a confirmation call when the output is turned on and call duration is 3 seconds.
CT1010 means that user NO1 will receive a confirmation call when the output is turned off and call duration is 10 seconds.
MS12 means that Toggle mode is activated for user NO1 which means that output status is changed with every call.
Task No1:
Configuring the system so that house heating system is turned on and turned off by the user (NO1) via free call. This user should
also receive free information about successful turning on or turning off of the heating system.
User
NO1
User
NO2
Flood detector
Heating
Controller
ESIM151
Confirmation
Call
3sek/10sek
Control
Call
XXXX_SMSEXTRA:COC1:CE1,CS1,CT113,CT1010,MS12