22
FOR ADVANCED USERS
All these features can be configured using program “ELDES Configuration Tool“
E. g. 4.
The company taking care of automatic systems needs to have information about critical breakdowns of mechanisms and has to
quickly react and eliminate the breakdown. There are three members of operating personnel (NO1), (NO2) and (NO3).
As per factory default settings SMS message sending feature in the case of alarm is enabled for all users until the first successful
delivery of the SMS message, it is necessary to remove users NO2 and NO3 and disable alarm calls for all users. It is also necessary to
invert Esim252 input from NO to NC mode so that alarm is given only when the signal disappears.
a) First of all a signal indicating gas boiler breakdown isconnected to Esim252 input Z1.
b) The following configuration SMS message must be sent to Esim252 system:
where SC23 means that alarm SMS message sending is disabled for users NO2, NO3 input Z1 is violated.
CC123 means that alarm calls are disabled for users NO1, NO2 and NO3 after input Z1 is violated.
We make an assumption that users NO4-NO5 were not entered to the system at all. LI1 means that NC -
“normally closed” - mode is enabled for the input.
Task No1:
Configuring the system so that operating personnel member (NO1) receives SMS message about the breakdown of gas boiler.
Working normally a gas boiler transfers a signal, and when it breaks down the signal is not transmitted.
XXXX_SMSEXTRA:Z1:SC23,CC123,LI1
Worker
NO1
Worker
NO2
Worker
NO3
Pump
Gas boiler
ESIM151
Automatic
system
Alarm
SMS
Fault
signal