10
3. Additional System Capabilities
3.1 Renaming Input Alarm/Restore Texts & Оutput Нames
Manufacturer initially set the following input alarm/restore texts and output names:
input Z1 alarm text - Zone1 Alarm, restore text - Restore1; input Z2 - Zone2 Alarm, restore text - Restore2; 0 input Z3 - Zone3 Alarm,
restore text - Restore3; input Z4 - Zone4 Alarm, restore text - Restore4; input Z5 - Zone5 Alarm, restore text - Restore5; output C1
name - Controller1; output C2 name - Controller2
E. g. in case input Z1 is violated, the system sends SMS message with the text: Zone1
Input alarm text
Input alarm text is changed by sending the following SMS mesaage:
E. G. XXXX_Z1:Intrusion though the door;Z2:Fire sensor alarm;
Texts can be changed all at once for all inputs, several of them or one by one. Maximum text for one
input text is 24 characters. The space is equal to one character. Each new text must be followed by a semi
colon. As semi colon is used for separating texts for different inputs. It cannot be used in the middle of
alarm texts, it can only be used at the end. Texts cannot be the same as configuration and control com-
mands, such as - ON, OFF, STATUS etc.
Input restore text
If you want to be notified by an SMS message when a violated zone is restored Restore mode must be turned on. The mode is turned
on by sending a particular SMS command. Please refer to chapter 3.9 or configuration program.
Input restore text is changed by sending the following SMS mesaage:
Output name can be changed by sending the following SMS message:
x - output number; possible values 1 - C1 or 2 - C2.
Output name cannot be followed by a semi colon. You cannot change input alarm/restore text and out-
put names at the same time.
E. g. XXXX_C1:PUMP
3.2 Enabling/Disabling Inputs
NOTE
Manufacturer set all the inputs activated, i. e. in mode ON.
USEFUL INFORMATION
The inputs can be enabled/disabled together or separately one by one.
Enabling Input
Any input can be enabled by sending the following SMS message:
XXXX_Z1:NewAlarmText;Z2:NewAlarmText;Z3:NewAlarmText;Z4:NewAlarmText;Z5:NewAlarmText;
XXXX_ZR1:NewRestoreText;ZR2:NewRestoreText;ZR3:NewRestoreText;ZR4:NewRestoreT
ext;ZR5:NewRestoreText;
XXXX_Cx:NewControllerName
XXXX_Z1:ON;Z2:ON;Z3:ON;Z4:ON;Z5:ON;
ESIM 252
XXXX_Z1:
trespaced;
Z2:
triggered
fire
detector;
ESIM 252
XXXX_C1:
PUMP
Содержание ESIM252