74
Elcom, spoločnosť s ručením obmedzeným, Prešov
Elcom, spoločnosť s ručením obmedzeným, Prešov
75
Uniq 150
Service manual
Service
manual
Uniq 150
3. According to linearity test: If test of linearity finish successfuly, stop the touch panel testing. If test of linearity
finished with wrong results, continue calibration by click on „Next“ button.
4. Using touch pointer pen follow the touch panel edge at direction shown with arrows as precisely as is possible (use
ruler). Always wait the arrows appears, when starting follow next edge. Tester accuracy is very important during the
calibration.
5. When all the edges is passed, press „Next“ button.
6. The 49-points calibration appears after saving previous calibration data. Always touch position of blue lines
intersection marked with black cross. After applying the pointer nib can be moved along the surface, until we reach
the exact location. The point position is assigned after lifting the pointer nib. Do not notice the red point
7. The linearity test starts immediately after 49-points calibration. Execute the test according to previously described
process.
Calibration
and/or
testing
repeat untill linearity deflection is less then 1% in both directions.