Installation and Connection Instructions
Heat Reclamation Connection
Connections
•
Tapping and return lines
•
Trenches and opening
Delivery/installation by installation
company or builder
Intermediate Circuit
•
Poss. groundwater pump
•
Establishing intermediate
circuit
incl.
heat
carrier
fill
Delivery/installation by installation company
Heat Pump
Bank
Terrain
Brine concrete
Sealing
borehole
Heat Source Systems
•
Establishing tapping
and return wells
•
Poss. groundwater
pump
•
Delivery/installation by
installation
company
or drilling company
Key
1 Poss.
filter
2 Slide
valve
3 Intermediate
exchanger
4 Manual air exhauster
5 Filling and draining valve
6 Safety valve
7 Thermometer
8 Expansion vessel
9 Manometer
11 Flow monitor
12 Circulating pump
13 Return valve
14 Poss. flow rate meter
15 Flow control valve
16 Antifrost thermostat
17 Submerged pump
18
Fine filter, mesh size
= 280 – 350 my
Installed in compact
heat pumps
L
When using groundwater or well water
as heat source, the following must be
observed:
-
Min. temperature > = 7°C
-
Filtered, clean water; provide water
filter in pressure line
L
Brine-side circulating pump, expansion
vessel, manometer, charging element,
and safety valve are already integrated
into the AQUATOP TC.
L
Lead safety line at an incline into
suitable collection container.
Water (with intermediate circuit)