7. COLLIMATION ELBO CONTROLLI srl
Preset E236+
28
7.3.4 MEASUREMENT WITH FIXED CIRCULAR RETICLE
Pressing again the
icon, it’s possible to display the fixed circle
reticule.
It will be possible to switch the radius of the standard inserts from 0,4
mm to 2,0 mm, matching the tool profile with the circumference arcs on
the reticule.
The measurement scale of the reticule is always referred to the concentric
circles’ radius, while the measure unit will be
mm
in “metric” mode,
inch
in “imperial” mode.
To exit from the “screen settings” menu, press the
icon again.
þ
Avoid inverting the movement direction during the collimation to achieve the best accuracy of the
measurement on fixed reticule.
7.4 SPECIAL MEASUREMENT CASES
E236+ can automatically recognize the orientation of the tool and measure it from the left or from the right
of the X axis, and from the top or the bottom of the Z axis. The operator has to do nothing when the tool
has been framed, the system analyses the image and sets the suitable collimation direction. The priority is
given to the measurement from the left of the X axis and from the top of the Z axis. This means that, in case
there are two valid measurements of the X axis, only the left measurement will be considered.
Tool profile
measured from the
right
The position of the
bars, indicates the
direction of collimation
Tool profile measured
from the right and bottom