As you can see, the residual inaccuracy value (S1, S2, S3, and S4) depends on the radius of the measured
tool and approximately corresponds to 0.01 mm, for tools having a radius of 20 mm, while it is smaller than
0,001 mm. For radii that are bigger than 80 mm.
Based on these considerations, we repeat that it is necessary to reach the best possible focusing and after
that search for the maximum tangency, that is, the maximum measurement being displayed.
7.3 COLLIMATION MODE
To carry out the measurement of tools, the E236+ has two modes of collimation: on a fixed central reticule
or automatic on all the screen.
In particular cases, in which E236+ isn’t able to identify correctly the measurement point, it will however,
be possible to effect measurements “by hand” of the particular display.
To set up the collimation mode desired press the camera function button/icon
, the relative menu
is composed of the following icons:
SHOOTING LENS
OPTIMAL
FOCAL
LENGTH
FOCUSING
MAXIMUM VALUE
SPINDLE
ROTATION
AXIS