background image

STEP 5: INSTALLING THE WATER BLOCK: 

STEP 5a: Intel LGA-775/1366 and AMD socket motherboard: 

1) Place motherboard on an even surface with front facing down. 

2) Install backplate rubber gasket - depending on your CPU platform 

(

see STEP 

4) 

- and place metal backplate for Intel LGA-1366 and AMD socket to the back 

of your motherboard 

RIBBED SIDE UP!

 Align the holes on the motherboard 

with holes on rubber gasket and backplate. 

3) Carefully rotate motherboard assembly with front side facing up with one 

hand while holding the backplate and rubber in place with the other hand. 

4) Install the rest of mounting system as per installation manual 

(see STEP 6) 

 

 

STEP 5b: Intel LGA-115x socket motherboard: 

1) Place motherboard on an even surface with front facing down. 

2) Install backplate rubber gasket depending on your CPU platform 

(

see STEP 4) 

- and place metal backplate for Intel LGA-115x socket to the back of your 

motherboard 

RIBBED SIDE UP!

 Align the holes on the motherboard with 

holes on rubber gasket and backplate. 

Make sure to orientate the rubber 

gasket to fit past the CPU socket ILM backplate.

 

3) Carefully rotate motherboard assembly with front side facing up with one 

hand while holding the backplate and rubber in place with the other hand. 

4) Install the rest of mounting system as per installation manual 

(see STEP 6) 

 

 

STEP 5c: Installing the mounting system: 

Intel Socket LGA-775/115x/1366 and AMD sockets:

 

Install the M4 thumb screws of the PreciseMount mounting system onto your 

motherboard. It is mandatory to put 0.7mm plastic washer underneath each 

of the M4 thumb screws. Tighten the M4 thumb screw to the metal backplate 

with your hands until you reach the end of the thread. Using tools (such as 

pliers) is not recommended! 

Intel Socket LGA-2011:

 

Install four (4) specific LGA-2011 M4 thumb screws into four M4 threaded 

stubs on the LGA-2011 socket integrated latch mechanism (ILM). The screws 

are to be installed using no tools (i.e. pliers). 

 

 

STEP 5d: Preparing your CPU and applying TIM: 
 

Cleaning the CPU:

 Once mounting mechanism is attached install the 

CPU  into  the  socket.  Wipe  the  CPU’s  contact  surface  (by  using  non–
abrasive cloth or 

Q-tip, as shown on sample photo). 

 

Applying thermal compound:

 EK recommends blob or line method 

of applying the enclosed Gelid GC-Extreme™ thermal compound to the 

CPU heatspreader (IHS) - see sample photo on right. The quantity of 
about two rice grains is just about right. There is no need to cover the 
whole  IHS.  Applying  too  much  thermal  grease  will  have  negative 
impact on the cooling performance! 

 
 

 

STEP 5e: Fastening the waterblock: 

Install the waterblock on your CPU. Place an enclosed compression spring 

and thumb nut over each M4 thumb screw. Start fastening two thumb nuts at 

a time, preferably in cross pattern and do not tighten them fully until all of 

them are partially screwed in. Then - using your fingers only - screw in all 

four thumb nuts until you reach the end of the thread. 

 

STEP 6:  CONNECTING WATER BLOCK TO THE COOLING 
CIRCUIT 

Carefully identify the direction of the flow in your circuit. For the EK-
Supremacy  series  water  block  to  operate  properly  the  G1/4  port 
nearest  to  the  center  of  the  water  block 

MUST  BE  USED  AS  THE 

INLET  PORT

.  EK  recommends  the  use  of  EK-CSQ  Fittings.  When 

using  fittings  other  than  EK-CSQ  series  please  use  hose  clamps  or 
appropriate  substitute  to  secure  the  tubing  to  the  barb.  The  use  of 

biocide  containing  and  corrosion  inhibiting  coolant  is  always 
recommended for any liquid cooling system. 

 

STEP 5: INSTALLING THE WATER BLOCK 
REQUIRED TOOLS 

-

 

allen key 2.5mm (enclosed) 

 

 

 

 

figure 1: Isometric view of backplate assembly for AMD Amx/FMx 

Metal 

backplate 

Rubber gasket 

figure 2: Isometric view of backplate 
assembly for LGA-115x 

Metal 

backplate 

Rubber gasket 

Motherboard 

PCB 

M4 thumb screw 

PVC 

washer 

LGA-2011 

M4 Thumb 

Screw 

 

Thumb nut 

Coiled spring 

EK-CSQ 

Fitting 

Tubing 

Motherboard 

PCB 

Содержание EK L Series

Страница 1: ......

Страница 2: ......

Страница 3: ......

Страница 4: ...mp reservoir combo EN Pump reservoir holders EN Compression fittings D AGB Pumpenaufsatz D Pumpe Tank Beh lter D Klemmverschraubung EN CPU mounting mechanism EN Coolant EN Tube D CPU K hler Montagemat...

Страница 5: ......

Страница 6: ...VIEW You will find the following mounting mechanism parts inside each EK Supreme LTX UNI CSQ water block STEP 3 OPTIONAL INSTALLING AMD MOUNTING PLATE Note specific instructions for AMD users In order...

Страница 7: ...on the LGA 2011 socket integrated latch mechanism ILM The screws are to be installed using no tools i e pliers STEP 5d Preparing your CPU and applying TIM Cleaning the CPU Once mounting mechanism is...

Страница 8: ...C 6 32 x 30 screws for each fan and screw them in Use enclosed 2mm allen key to tighten the screws in clockwise direction D Nehmen Sie die L fter und verschrauben Sie diese mit dem Radiator Um maximal...

Страница 9: ...hat suits you best D Sie k nnen L fter sowie auch Radiator an denjenigen stellen des Geh uses befestigen die blicherweise f r Installation von L ftern vorgesehen sind wobei wir in diesem Fall die Mont...

Страница 10: ...von blosser Hand an Die dadruch aufgewendete Kraft ist aureichend D Sie k nnen diese Einheit alternativ auch it dem Geh use verschrauben Hierzu verwenden Sie die im Lieferumfang enthaltenen M4x6 Schr...

Страница 11: ...n D Von Auge nachmessen wie lange das ben tigte Schlauch St ck sein soll D Schlauch nach der entsprechenden L nge abschneiden EN Install the compression fitting to both G1 4 extender openings on the r...

Страница 12: ...rd EN EK Cable Y splitter is not included within this kit It is just shown as an example how to connect wiring in case of multiple fans D EK Cable Y splitter ist nicht im Lieferumfang von Kit enthalte...

Страница 13: ...erden D Ist der gesamte Kreislauf bef llt kann die Pumpe einige Male ein und ausgeschaltet werden um Luftblasen aus dem Kreislauf zu entfernen EN Close the reservoir by screwing in the top acetal endc...

Страница 14: ...n the container and gently blow into the other tube to additionally drain the system D Das Wasser aus dem Ausgleichsbeh lter in den Auffangbeh lter fliessen lassen D Die beiden mit der Ausgleichsbeh l...

Отзывы: