PRODUCT MAINTENANCE
04/2022
51
NP-DK50-Nx2VTM-AD-EN-6_04-2022
18.18. Inspecting the cooler and fan
The equipment, in particular the compressor
fan, cooler fan, and the cooler, must be kept
clean to ensure efficient drying. Remove dust
from the surface of the cooling fins and fans
by vacuuming or blowing down with
compressed air.
18.19. Replacement of solenoid valves
Risk of electric shock.
Shut off the compressed air
source, turn off the equipment
and disconnect it from the
mains before working on the
equipment.
Working
with
pressurised
pneumatic components poses a
risk of injury.
Disconnect the equipment from
the mains and vent the pressure
in the equipment and the
pneumatic
system
to
zero
before
working
on
the
equipment.
In normal operation, the solenoid valves in the
bottom of the dryer must be replaced at the
defined interval.
Turn off the compressor.
Check the pressure in the dryer.
If the dryer chambers are under
pressure, proceed in accordance with
Chapter 18.13.
Unscrew the 1 screw from the valve
connector.
Disconnect the valve connector (1).
Unscrew the 4 screws (2).
Remove the solenoid valve (3).
Remove the valve seal (4-1) from the
body.
Physically clean the valve seat surface
to remove any impurities.
Physically clean the 16 screws (2) to
remove the thread locking adhesive.
Install the solenoid valve (Fig. 32).
Install the new valve seal (4-1).
Install the new solenoid valve using
the 4 screws (2) and use a thread
locking adhesive on the threads of the
screws (such as Loctite 243).
Reattach the solenoid valve connector
and attach with a screw (1).
Switch on the compressor.
Check for any dryer leaks.
Содержание DK50 4x2VT/M
Страница 1: ...DK50 4x2VT M DK50 6x2VT M User manual...
Страница 2: ......
Страница 10: ...PRODUCT DESCRIPTION NP DK50 Nx2VTM AD EN 6_04 2022 10 04 2022 DK 50 6x2VT M...
Страница 13: ...PRODUCT DESCRIPTION 04 2022 13 NP DK50 Nx2VTM AD EN 6_04 2022 Fig 1 Compressor with adsorption dryer...
Страница 14: ...PRODUCT DESCRIPTION NP DK50 Nx2VTM AD EN 6_04 2022 14 04 2022 Fig 2 Adsorption dryer...
Страница 17: ...TECHNICAL DATA 04 2022 17 NP DK50 Nx2VTM AD EN 6_04 2022 Dependence of compressor output on working pressure...
Страница 32: ...INSTALLATION NP DK50 Nx2VTM AD EN 6_04 2022 32 04 2022 15 PNEUMATIC DIAGRAMS DK50 4x2VT M...
Страница 33: ...INSTALLATION 04 2022 33 NP DK50 Nx2VTM AD EN 6_04 2022 DK50 6x2VT M...
Страница 58: ......
Страница 59: ......