10. INSTALLATION CONDITIONS
The compressor may only be installed
and operating in dry, well-ventilated
and clean environments under the
conditions specified in the Technical
Data chapter.
Risk of damage to the device.
The equipment may not be
operated
outdoors
or
in
otherwise
wet
or
damp
environments.
Risk of explosion.
Do not use the equipment in the
presence of explosive gases,
dust or combustible liquids.
The compressor must be installed so
that it is accessible at all times for
operating and maintenance. Please
ensure that the nameplate on the
device is readily accessible.
The compressor must stand on a flat,
sufficiently stable base (be aware of
the weight of the compressor, see the
Technical Data chapter).
The compressor on the operator’s side
must be at least 70 cm from the wall to
allow air flow for cooling purposes and
to ensure the safety of the operator
and maintenance personnel.
Approximately 70% of the electrical
energy used by the compressor
aggregates is converted to heat, and
therefore the rooms in which the
compressor is installed must have
additional
ventilation
to
provide
sufficient air exchange for cooling
purposes (see the Technical Data
chapter).
Burn or fire hazard! Caution!
Hot surface!
Portions of the compressor,
dryer and connecting hoses
between
the
dryer
and
compressor may be hot and
reach hazardous temperatures
during compressor operation
that may harm materials or
operating staff.
High temperature hazard
Placing air flow impediments
upstream or downstream of the
cooler
is
prohibited.
The
temperature of internal and
external parts of the equipment
may rise to hazardous levels.
Ensure the power cords and air
hoses are not damaged. The
power cord must not show
signs of stress and must be
kept without tension (placing
any objects on it is prohibited),
and subjecting the cord to
external heat in any form is
prohibited.
Содержание DK50 4x2VT/M
Страница 1: ...DK50 4x2VT M DK50 6x2VT M User manual...
Страница 2: ......
Страница 10: ...PRODUCT DESCRIPTION NP DK50 Nx2VTM AD EN 6_04 2022 10 04 2022 DK 50 6x2VT M...
Страница 13: ...PRODUCT DESCRIPTION 04 2022 13 NP DK50 Nx2VTM AD EN 6_04 2022 Fig 1 Compressor with adsorption dryer...
Страница 14: ...PRODUCT DESCRIPTION NP DK50 Nx2VTM AD EN 6_04 2022 14 04 2022 Fig 2 Adsorption dryer...
Страница 17: ...TECHNICAL DATA 04 2022 17 NP DK50 Nx2VTM AD EN 6_04 2022 Dependence of compressor output on working pressure...
Страница 32: ...INSTALLATION NP DK50 Nx2VTM AD EN 6_04 2022 32 04 2022 15 PNEUMATIC DIAGRAMS DK50 4x2VT M...
Страница 33: ...INSTALLATION 04 2022 33 NP DK50 Nx2VTM AD EN 6_04 2022 DK50 6x2VT M...
Страница 58: ......
Страница 59: ......