18.16. Replacement of the logic valve ball
Turn off the compressor.
Check the pressure in the dryer.
If the dryer chambers are under
pressure, proceed in accordance with
Chapter 18.13.
Unscrew the 4 screws (1) and remove
the cover (2).
Remove the ball cover (3).
Replace the ball (4).
Check the nozzles (5) and clean as
necessary.
Reverse
the
procedure
to
reassemble.
Check for leaks and the operation of
the logic valve and nozzles
– check for
the cyclical switching of the chambers.
Fig. 29: Replacement of the logic vave ball
18.17.
Replacement of the dryer’s
silencer
Working
with
pressurised
pneumatic components poses a
risk of injury.
Operating
the
equipment
without
silencers
generates
high levels of noise. Only
replace silencers when the
equipment is shut down.
Unscrew the silencer (1).
Install a new silencer.
Fig. 30: Replacement of the silencer
Содержание DK50 4x2VT/M
Страница 1: ...DK50 4x2VT M DK50 6x2VT M User manual...
Страница 2: ......
Страница 10: ...PRODUCT DESCRIPTION NP DK50 Nx2VTM AD EN 6_04 2022 10 04 2022 DK 50 6x2VT M...
Страница 13: ...PRODUCT DESCRIPTION 04 2022 13 NP DK50 Nx2VTM AD EN 6_04 2022 Fig 1 Compressor with adsorption dryer...
Страница 14: ...PRODUCT DESCRIPTION NP DK50 Nx2VTM AD EN 6_04 2022 14 04 2022 Fig 2 Adsorption dryer...
Страница 17: ...TECHNICAL DATA 04 2022 17 NP DK50 Nx2VTM AD EN 6_04 2022 Dependence of compressor output on working pressure...
Страница 32: ...INSTALLATION NP DK50 Nx2VTM AD EN 6_04 2022 32 04 2022 15 PNEUMATIC DIAGRAMS DK50 4x2VT M...
Страница 33: ...INSTALLATION 04 2022 33 NP DK50 Nx2VTM AD EN 6_04 2022 DK50 6x2VT M...
Страница 58: ......
Страница 59: ......