15
Chapter 2 Adjusting Screens
"Comm." tab
Item
Adjustable
Range
Description
RS232 Interface
Standard
SCOM
Selects the communication pattern of RS-232C.
RS485
Interface
Mode
MODBUS
The communication pattern of RS-485
Slave Address
1 to 247
Specifies a slave address.
Baudrate
19200 Baud
9600 Baud
Specifies the transmission rate.
Parity
Even
Odd
Off
Specifies the parity check method.
Bus Topology
Two-Wire
Four-Wire
Selects half-duplex communication or full-duplex
communication.
Bus Termination Off
On
Set this to "Off" if a terminating device is installed on
the communication path.
SNMP
IP Address
0.0.0.0 to
255.255.255.255
Configures the network settings.
Subnet Mask
Standard
Gateway
Primary DNS
Server
GET Community
String
(Eight alphabetical
letters)
Specifies the community name used for the GET
request and SET request.
SET Community
String
Restart SNMP / RS485
Communication
-
Restart communication to apply the settings. Be sure to
run this option when the "RS485 Interface" or "SNMP"
settings have been configured.
Note
• The settings are also applied when the main power of
the monitor is turned off and back on.
"Info" tab
You can check the monitor information (such as serial number, firmware version, usage time, resolution,
and input signal).